Case: T09FR03783
Case Details
Entered Date:
12/16/2009
Applicant:
NANSU LLC
Description:
Full inspection done 12/16/09; Carrie Alexander - Manager, 296-6850; A-2 occupancy; Hoods are current, and report sent to SDU. Good inspection.
Completed Inspections
Case Status: COMPLETE
Case Number: T09FR03783
Case Description: INSPECTION
Total Completed Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2009 | VIOL - EMERGENCY PLAN/PREPARE | BCOBB | Approved | Employees knowledge of "Pull Station": TFC2006/ 406.3.3 Fire safety training. Employees assigned fire-fighting duties shall be trained to know the locations and proper use of portable fire extinguishers or other manual fire-fighting equipment and the protective clothing or equipment required for its safe and proper use. ______Hold a class for all employees on the location and use of the "pull station" for the hood system. Have a roster of attendees with the date, subjects covered, and instructor, for my review. [Note: It is a good idea to revisit this information periodically at your employees meeting.] |
| 12/16/2009 | INSP - FULL | BCOBB | Approved | Please correct the following Tucson Fire Code violations: |
| 12/16/2009 | VIOL - FIRE PROTECTION SYSTEMS | BCOBB | Approved | Hood system: 904.11.6 Operations and maintenance. Commercial cooking systems shall be operated and maintained in accordance with this section. ______ Fryer need to be under hood and nozzles at al times! |
| 12/16/2009 | VIOL - FIRE RESIST.RATED CONST | BCOBB | Approved | Missing, Damaged or Moved ceiling tiles: TFC2006/ 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. _____Replace missing or damaged ceiling tiles. |
| 12/16/2009 | VIOL - BUILDING SVCS & SYSTEMS | BCOBB | Approved | Loose / exposed wires: TFC2006 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. ______Fix outside wires so it is not an electrical or trip hazard - in an approved manner. |