Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

12/14/2009

Applicant:

BROADWAY PARTNERS 128 LLC

Description:

Full inspection done 12/14/09; Paul Nagy - maint sup - 885-3590; R2 / B occupancy;

Completed Inspections

Case Status: COMPLETE
Case Number: T09FR03762
Case Description: INSPECTION
Total Completed Inspections - 6
End Date Description Inspector Results Comments
12/14/2009 VIOL - MEANS OF EGRESS BCOBB Approved Double keyed lock on door: 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ______ Remove Keyed dead bolt from wood door in game room. [replace with "thumb turn" type]
12/14/2009 VIOL - FIRE PROTECTION SYSTEMS BCOBB Approved Poolside emergency phone: TFC2006/ 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. ______ 911 Phone shall be maintained in a working order.
12/14/2009 VIOL - BUILDING SVCS & SYSTEMS BCOBB Approved Open space in electrical panel: TFC2006 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. _____Place an approved "blank" in the space.
12/14/2009 VIOL - BUILDING SVCS & SYSTEMS BCOBB Approved Open wire boxes/ splices: TFC2006 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. ______Cover wires in an approved manner.
12/14/2009 VIOL - BUILDING SVCS & SYSTEMS BCOBB Approved Extension cords: TFC2006/ 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. _____ Remove or replace with approved fused power strip.
12/14/2009 INSP - FULL BCOBB Approved Please correct the following Tucson Fire Code violations: