Status:

COMPLETE

Type:

INSPECTION

Entered Date:

10/26/2009

Applicant:

SANTISTEVAN FAMILY TR

Description:

Automotive Recalibration Full Inspection conducted 10/21/09 I have received a copy of this report and understand the corrections needed: _________________ Business Rep: Sam Santistevan, Phone: 747-9229 Inspector: __________________, Captain: ___________ David Greenleaf, MA 23 If you have any questions please call 791-4502. Approved: ________ Re-inspection: __/__/__ (or after) Certificate of Occupancy: NOT CURRENT Occ Group B-1 per CofO 10/2/90 (UFC '88) Current Use: S-1 Please correct the following Tucson Fire Code violations:

Outstanding Inspections

Case Number: T09FR03365
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
10/21/2009 INSP - FULL dgreenl1 Violation TFC 605.6 - Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. _____ Install approved cover plate for outlet - office _____ Provide covers for missing circuit breakers Chapter 906, Portable Fire Extinguishers TFC 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. (Professional maintenance yearly, manual inspection monthly, affix a tag to the extinguisher with records of these activities.) _____ Extinguishers shall be inspected by occupant monthly and professionally serviced annually. A tag shall be affixed to the extinguisher with records of these activities. TFC 1008.1.8 - Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Exceptions: In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in places of religious worship, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided: 2.1. The locking device is readily distinguishable as locked, 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch high on a contrasting background, 2.3. The use of the key-operated locking device is revokable by the fire code official for due cause. _____ Remove deadbolt from East bay door and/or replace it with an approved locking device.