Full Fire Prevention Inspection
Outstanding Inspections
Case Number: T09FR01932
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 8
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FULL | None | Not Inspected | ||
| 06/11/2009 | VIOL - PRECAUTION AGAINST FIRE | DSIWARSKI | Violation | IFC.304.1.2 Vegetation. Weeds, grass, vines or other growth that is capable of being ignited and endangering property, shall be cut down and removed by the owner or occupant of the premises. Vegetation clearance requirements in urban-wildland interface areas shall be in accordance with the International Wildland-Urban Interface Code. ____Weeds need to be cut/cleaned up on North side of business to abate potential fire hazard. |
| 06/11/2009 | VIOL - BUILDING SVCS & SYSTEMS | DSIWARSKI | Violation | IFC.605.4 Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. ____Remove/replace multi-plug adapter in storage room. IFC.05.4.2 Power supply. Relocatable power taps shall be directly connected to a permanently installed receptacle. ____Relocatable power strip by water cooler needs to be UL1363 approved. |
| 06/11/2009 | VIOL - BUILDING SVCS & SYSTEMS | DSIWARSKI | Violation | IFC.605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. ____Extension cord being used as permanent wireing by front desk. ____Extension cord being used as permanent wireing by refrigerator. |
| 06/11/2009 | VIOL - FIRE PROTECTION SYSTEMS | DSIWARSKI | Violation | IFC.906.2 General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ____Two fire extinguishers in storage room and service/repair area needs to be maintained/service. |
| 06/11/2009 | VIOL - MEANS OF EGRESS | DSIWARSKI | Violation | IFC.1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background... ____Sign over front door to read "THIS DOOR IS TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". |
| 06/11/2009 | VIOL - HAZARDOUS MATERIALS,GEN | DSIWARSKI | Violation | Comment: Address lettering requirements must comply with the Pima County Address Display Requirements (see attachments). |
| 06/11/2009 | VIOL - HAZARDOUS MATERIALS,GEN | DSIWARSKI | Violation | IFC.2703.6 Signs. Signs and markings required by Sections 2703.5 and 2703.5.1 shall not be obscured or removed, shall be in English as a primary language or in symbols allowed by this code, shall be durable, and the size, color and lettering shall be approved. ____The 55 gallon and 5 gallon drums must be labeled with the name of the products stored. |