Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

06/11/2009

Applicant:

RONA & HILA INC

Description:

Full Fire Prevention Inspection

Outstanding Inspections

Case Number: T09FR01932
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 8
End Date Description Inspector Results Comments
INSP - FULL None Not Inspected
06/11/2009 VIOL - PRECAUTION AGAINST FIRE DSIWARSKI Violation IFC.304.1.2 Vegetation. Weeds, grass, vines or other growth that is capable of being ignited and endangering property, shall be cut down and removed by the owner or occupant of the premises. Vegetation clearance requirements in urban-wildland interface areas shall be in accordance with the International Wildland-Urban Interface Code. ____Weeds need to be cut/cleaned up on North side of business to abate potential fire hazard.
06/11/2009 VIOL - BUILDING SVCS & SYSTEMS DSIWARSKI Violation IFC.605.4 Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. ____Remove/replace multi-plug adapter in storage room. IFC.05.4.2 Power supply. Relocatable power taps shall be directly connected to a permanently installed receptacle. ____Relocatable power strip by water cooler needs to be UL1363 approved.
06/11/2009 VIOL - BUILDING SVCS & SYSTEMS DSIWARSKI Violation IFC.605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. ____Extension cord being used as permanent wireing by front desk. ____Extension cord being used as permanent wireing by refrigerator.
06/11/2009 VIOL - FIRE PROTECTION SYSTEMS DSIWARSKI Violation IFC.906.2 General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ____Two fire extinguishers in storage room and service/repair area needs to be maintained/service.
06/11/2009 VIOL - MEANS OF EGRESS DSIWARSKI Violation IFC.1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background... ____Sign over front door to read "THIS DOOR IS TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED".
06/11/2009 VIOL - HAZARDOUS MATERIALS,GEN DSIWARSKI Violation Comment: Address lettering requirements must comply with the Pima County Address Display Requirements (see attachments).
06/11/2009 VIOL - HAZARDOUS MATERIALS,GEN DSIWARSKI Violation IFC.2703.6 Signs. Signs and markings required by Sections 2703.5 and 2703.5.1 shall not be obscured or removed, shall be in English as a primary language or in symbols allowed by this code, shall be durable, and the size, color and lettering shall be approved. ____The 55 gallon and 5 gallon drums must be labeled with the name of the products stored.