Case: T09FR01924
Case Details
Entered Date:
06/11/2009
Applicant:
WIESE CARL A & NANCY A TR
Description:
Full Fire Prevention Inspection
Outstanding Inspections
Case Number: T09FR01924
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FULL | None | Not Inspected | ||
| 06/11/2009 | VIOL - BUILDING SVCS & SYSTEMS | DSIWARSKI | Violation | IFC.605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the code official responsible for enforcement of the ICC Electrical Code. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. ____Open electrical wires on the west side front of building must be encased. ____Cover plate required on juncton box east side, front of building. ____Remove stored equipment to allow for access to electrical panel. ____Repair/service conduit on west side of building across from exit. ____Secure wall outlet on east wall. ____Cover plate needed on outlet in room by rear exit. ____Extension cords shall not be used as permanent wireing. |
| 06/11/2009 | VIOL - MEANS OF EGRESS | DSIWARSKI | Violation | IFC.1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ____Replace rear exit key lock. IFC.1027.3 Exit sign illumination. Exit signs shall be internally or externally illuminated. The face of an exit sign illuminated from an external source, shall have an intensity of not less than 5 foot-candles (54 lux). Internally illuminated signs shall provide equivalent luminance and be listed for the purpose. ____Service/repair rear door exit sign |
| 06/11/2009 | VIOL - MEANS OF EGRESS | DSIWARSKI | Violation | IFC.1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists:.. 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background... ____Place sign on front door, "THIS DOOR IS TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" |