Case: T09FR01878
Case Details
Entered Date:
06/05/2009
Applicant:
STAFF OF LIFE LLC
Description:
Full fire Prevention Inspection
Outstanding Inspections
Case Number: T09FR01878
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 7
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
INSP - FULL | None | Not Inspected | ||
VIOL - DRY CLEANING | None | Not Inspected | ||
06/05/2009 | VIOL - FIRE SERVICE FEATURES | DSIWARSKI | Violation | IFC.504.2 Maintenance of exterior doors and openings. Exterior doors and their function shall not be eliminated without prior approval. Exterior doors that have been rendered nonfunctional and that retain a functional door exterior appearance shall have a sign affixed to the exterior side of the door with the words THIS DOOR BLOCKED. The sign shall consist of letters having a principal stroke of not less than 0.75 inch (19.1 mm) wide and at least 6 inches (152 mm) high on a contrasting background. Required fire department access doors shall not be obstructed or eliminated. Exit and exit access doors shall comply with Chapter 10... ____Back room door on West side shall be signed "THIS DOOR BLOCKED" on the outside and inside "THIS IS NOT AN EXIT" |
06/05/2009 | VIOL - BUILDING SVCS & SYSTEMS | DSIWARSKI | Violation | IFC.605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. ____Extension cords on West side of back room shall not be used as permanent wireing. ____Back bedroom area extension cord to shall not be used as permanent wireing. |
06/05/2009 | VIOL - FIRE RESIST.RATED CONST | DSIWARSKI | Violation | IFC.703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. ____Repair hole in ceiling in back room. |
06/05/2009 | VIOL - FIRE PROTECTION SYSTEMS | DSIWARSKI | Violation | IFC.906.2 General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ____Portable fire extinguisher must be serviced/maintained. |
06/05/2009 | VIOL - MEANS OF EGRESS | DSIWARSKI | Violation | IFC.1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. ___Remove drop down bar hardware on rear door East side. |