Full Inspection conducted 4/21/09 I have received a copy of this report and understand the corrections needed: ________________ Business Owner: Majic Farhang, Phone: 747-7335 Inspector: __________________, Captain: _____________ David Greenleaf, MA 23 If you have any questions please call 791-4502. Approved: ________ Re-inspection: __/__/__ (or after)

Outstanding Inspections

Case Number: T09FR01363
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
04/21/2009 INSP - FULL DGREENLE Correction Required PrFF C. Clayton assisting. Please correct the following violations of the Tucson Fire Code: TFC 901.6 - Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. _____ Extinguishers shall be inspected by occupant monthly and professionally serviced annually. A tag shall be affixed to the extinguisher with records of these activities. TFC 906.5 - Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. TFC 906.6 - Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. TFC 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. 906.9 Height above floor. Portable fire extinguishers having a gross weight not exceeding 40 shall be installed so that its top is not more than 5 feet above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds shall be installed so that its top is not more than 3.5 feet above the floor. The clearance between the floor and the bottom of installed hand-held extinguishers shall not be less than 4 inches. _____ Mount extinguishers in an approved manner TFC 605.6 - Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. _____ Install approved cover plate for junction box - South wall _____ Install approved cover plate for junction box - above N/W door. _____ Install approved switchplate - bathroom TFC 1008.1.8 - Door operations. ... egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____ Replace double-keyed deadbolt with thumb-turn mechanism on egress side - Bathroom/rear exit. TFC 315.2.4 - Attic, under-floor and concealed spaces. Attic, under-floor and concealed spaces used for storage of combustible materials shall be protected on the storage side as required for 1-hour fire-resistance-rated construction. ... Storage shall not be placed on exposed joists. _____ Provide approved 1-hour fire-resistance rated material above hallway to rear exit or remove combustible storage. TFC 605.4.2 - Power supply. Relocatable power taps shall be directly connected to a permanently installed receptacle. _____ Plug power strip serving compuer directly into wall outlet. TFC 605.1 - Abatement of electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the code official responsible for enforcement of the ICC Electrical Code. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. _____ Repair 220v (welder) outlet - NE corner TFC 605.5 ...flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. _____ Electrical wiring serving lift behind shop shall be installed according to the Tucson Electrical Code. TFC 703.1.1 - Fireblocking and draftstopping. Required fireblocking and draftstopping in combustible concealed spaces shall be maintained to provide continuity and integrity of the construction. _____ Replace missing ceiling tiles or remove remaining ones to eliminate combustible void. TFC 2703.3 - Release of hazardous materials. Hazardous materials in any quantity shall not be released into a sewer, storm drain, ditch, drainage canal, creek, stream, river, lake or tidal waterway or on the ground, sidewalk, street, highway or into the atmosphere. _____ Provide procetive materials and measures to insure that used oil/antifreeze does not reach the ground. TFC 2703.3.1.4 - Responsibility for cleanup. The person, firm or corporation responsible for an unauthorized discharge shall institute and complete all actions necessary to remedy the effects of such unauthorized discharge, whether sudden or gradual, at no cost to the jurisdiction. When deemed necessary by the fire code official, cleanup may be initiated by the fire department or by an authorized individual or firm. Costs associated with such cleanup shall be borne by the owner, operator or other person responsible for the unauthorized discharge. _____ Clean up contaminated soil at base of used oil/antifreeze containers. 2703.4 - Material Safety Data Sheets. Material Safety Data Sheets (MSDS) shall be readily available on the premises for hazardous materials regulated by this chapter. _____ Provide MSDS for all hazardous materials used and stored on the property. (Safety-Kleen 105 solvent - parts cleaner) TFC 3405.3.6.2 - Listed and approved machines. Parts cleaning and degreasing conducted in listed and approved machines in accordance with Section 3405.3.6.1 shall be in accordance with Sections 3405.3.6.2.1 through 3405.3.6.2.7. TFC 3405.3.6.2.7 - Installation. Machines shall be installed in accordance with their listings. _____ Provide manufacturer's documantation for safe listed installation and use of parts cleaner and solvent. _____ Including, but not limited to, moving parts cleaner away from grinder per warning clearly indicated on cover.

Completed Inspections

Case Status: COMPLETE
Case Number: T09FR01363
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
08/10/2009 INSP - REINSPECTION DGREENLE Approved