Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

02/19/2009

Applicant:

BARCLAY CRESWIN PROPERTIES I LLC

Description:

Panda Express fire inspection.

Outstanding Inspections

Case Number: T09FR00697
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
02/19/2009 INSP - FULL JLOYA Violation Correct the following fire code violations found during life/safety fire inspection. Thank you for your cooperation, for any questions please contact inspector Jorge Loya @ 791-4502 ext. 146
02/19/2009 VIOL - PRECAUTION AGAINST FIRE JLOYA Violation 315.2.1 - Ceiling clearance. Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings.
02/19/2009 VIOL - FIRE PROTECTION SYSTEMS JLOYA Violation 904.11.6.3 - Hoods, grease-removal devices, fans, ducts and other appurtenances shall be cleaned at intervals necessary to prevent the accumulation of grease. Cleanings shall be recorded, and records shall state the extent, time and date of cleaning. Such records shall be maintained on the premises.
02/19/2009 VIOL - MEANS OF EGRESS JLOYA Violation 1003.6 - Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of a means of egress system shall not be diminished along the path of egress travel. _____ Clear exit path, and maintain it this way.

Completed Inspections

Case Status: COMPLETE
Case Number: T09FR00697
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/23/2009 INSP - REINSPECTION JLOYA Approved Compliance obtained with report of hood cleaning received via e-mail from state fire protection out of queen creek az after pre-citation was issued.