Case: T09FR00405
Case Details
Entered Date:
01/29/2009
Applicant:
DP'S LAND MANAGEMENT CO INC
Description:
Full Fire Inspection
Outstanding Inspections
Case Number: T09FR00405
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 8
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/29/2009 | INSP - FULL | JNAGORE | Violation | |
01/29/2009 | INSP - FULL | JNAGORE | Violation | 1017.5Fire resistance rated corridorsshall be continuous from entry to exit. |
01/29/2009 | INSP - FULL | JNAGORE | Violation | 315.2 Storage in buildings. Storage of combustible materials in buildings shall be orderly. Storage shall be separated from heaters or heating devices by distance or shielding so that ignition cannot occur. 315.2.1 Ceiling clearance. Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings. |
01/29/2009 | INSP - FULL | JNAGORE | Violation | 605.3.1 Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating ELECTRICAL ROOM or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Identify electrical room door. |
01/29/2009 | INSP - FULL | JNAGORE | Violation | 605.3Working space and clearance. A working space of not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be provided in front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the working space shall not be less than the width of the equipment. No storage of any materials shall be located within the designated working space. Remove all combustible materials. |
01/29/2009 | INSP - FULL | JNAGORE | Violation | 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance- rated assemblies shall be protected by self-closing or automatic- closing doors of approved construction meeting the fire protection requirements for the assembly. Replace all missing celing tiles. |
01/29/2009 | INSP - FULL | JNAGORE | Violation | 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. Mount Fire extinguisher or remove. |
01/29/2009 | INSP - FULL | JNAGORE | Violation | AddressingPima Co. address Display Requirements. Commercial buildings less than 50 feet from the street require12 inch numbers displayed on the building. |