Case: T09DV06980
Case Details
Entered Date:
12/18/2009
Applicant:
RS REVOCABLE LIVING TR
Description:
HAZARDOUS WATER HEATER, OUTLETS, NO SMOKE DET, WOP
Outstanding Inspections
Case Number: T09DV06980
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 3
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/18/2009 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | KTARKET | Item initialized | |
12/18/2009 | NPO(PL)-WATER HEATERS | KTARKET | Item initialized | |
12/18/2009 | NPO - SMOKE ALARMS | KTARKET | Item initialized |
Completed Inspections
Case Status: COMPLIAN
Case Number: T09DV06980
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/17/2009 | INSP - INITIAL CODE ENFORCMENT | ASMITH | Approved | HAZARDOUS WATER HEATER, OUTLETS, NO SMOKE DET, WOP |
10/13/2010 | INSP - FOLLOW UP CODE ENFORCE | ASMITH | Approved | All inspection were completed by DSD on 9/27/2010. Case is closed. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T09DV06980
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date | Name |
10/14/2010 | NOTICE OF VIOLATION ISSUED |
10/13/2010 | VIOLATION CLOSED |
04/01/2010 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
04/01/2010 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
04/01/2010 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
04/01/2010 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |