Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

11/06/2009

Applicant:

BARTON JEAN M TR

Description:

House Fire. Alarm code 09-68033

Outstanding Inspections

Case Number: T09DV06313
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 8
End Date Description Inspector Results Comments
12/09/2009 NPO(EL)-MAIN/PANEL/SUB/DISCONT LPUMPHRE Item closed
12/09/2009 NPO(EL)-WIRING/SWITCH/OUTLT/FX LPUMPHRE Item closed
12/09/2009 NPO(PL)-GAS SUPPLY/CONNECT LPUMPHRE Item closed
12/09/2009 NPO(HC)-HEATING & VENTILATION LPUMPHRE Item closed
12/09/2009 NPO - EGRESS LPUMPHRE Item closed
12/09/2009 NPO - EXT. BUILDING MAINTENANC LPUMPHRE Item closed
12/09/2009 NPO - WORK WITHOUT PERMIT LPUMPHRE Item closed
12/09/2009 NPO - INT. BUILDING MAINTENANC LPUMPHRE Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T09DV06313
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/06/2009 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved EMERGENCY CALL OUT FOR RESIDENTIAL FIRE (INSPECTORS PUMPHREY AND STEVENS). INSPECTION SHOWED SMALL PORCH FIRE THAT ENTERED INTO EAVES AND ATTIC OVER KITCHEN AND POSSIBLY BEDROOM TO THE EAST. BUILDING DAMAGE INCLUDES BROKEN PORCH WINDOW, HOLES IN KITCHEN AND BEDROOM CEILINGS. FIRE DAMAGE DOES NOT APPEAR TO HAVE AFFECTED STRUCTURAL MEMBERS ON PORCH AT THIS TIME, BUT WILL NEED REVIEW BY A LICENSED CONTRACTOR. TEP DISCONNECTED ELECTRICAL; POSSIBLE DAMAGE TO WIRING IN EAST BEDROOM. THIS BEDROOM IS AN UNFINISHED CARPORT CONVERSION INTO TWO BEDROOMS WITH ADDED ELECTRICAL; CONSTRUCTION TECHNIQUES SUGGEST IT WAS DONE WITHOUT PERMITS. DOORS TO OUTSIDE ARE INSTALLED INCORRECTLY AND ONE DOOR ON EAST SIDE HAS DEADBOLT KEYED FROM THE OUTSIDE; AN EGREE HAZARD. RESIDENCE HAS AN ORIGINAL 60 AMP SERVICE AND WILL REQUIRE A PERMIT TO REINSTATE, WHICH WILL INCLUDE AN UPGRADE TO A 100 AMP SERVICE (APPEARS TO HAVE BEEN STARTED) AND PERMIT FOR ADDITION; THE UNPERMITTED ADDED WIRING DRAWS ADDITIONAL LOAD ON THE 60 AMP SERVICE. TENANT ADVISES THAT THE GAS HAS BEEN TURNED OFF PREVIOUSLY TO SAVE MONEY AND WAS USED FOR COOKING ONLY, NOT HEATING. WATER HEATER MAY BE GAS; HOT WATER IS REQUIRED; SERVICE MUST BE ON AND AVAILABLE; ACTUAL USAGE WILL BE UP TO OCCUPANTS. TENANT, MR. PHIL SALAZAR, WAS GIVEN IDEMIFICATION, ORDER TO VACATE, AND INITIAL NOV REGARDING UTILITIES.
12/07/2009 INSP - FOLLOW UP CODE ENFORCE LPUMPHRE Approved COMPLIANT: INSPECTION CONFIRMED THAT BEDROOMS AND ADDED WALL/CEILING FAN HAS BEEN REMOVED FROM ORIGINALLY PERMITTED CARPORT STORAGE ENCLOSURE. OWNER ADVISED THAT CONVERSION TO LIVING SPACE WILL REQUIRE PERMITS. ELECTRICAL UPGRADE INSTALLED WITH FINALED PERMIT. REAR PORCH REMOVED AND CEILING REPAIRED. OWNER ADVISED THAT ANY NEW PORCH BUILT WILL REQUIRE A PERMIT. LRP

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T09DV06313
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
11/10/2009 CONTACTED BY PHONE
12/09/2009 VIOLATION CLOSED
11/24/2009 RESEARCH
11/06/2009 8-5 CITY COMM EMERGENCY