Case: T09DV05476
Case Details
Entered Date:
09/21/2009
Applicant:
KREIENKAMP JANET I
Description:
HOUSE FIRE CALL#0958000
Outstanding Inspections
Case Number: T09DV05476
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2010 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | DCOX | Item closed | |
| 10/21/2010 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | DCOX | Item closed | |
| 10/21/2010 | NPO - EXT. BUILDING MAINTENANC | DCOX | Item closed | |
| 10/21/2010 | NPO - INT. BUILDING MAINTENANC | DCOX | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T09DV05476
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/21/2009 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Approved | VISUAL INSPECTION, FIRE DAMAGE TO ENCLOSED CARPORT, EXTERIOR SIDING WAS REMOVED FIRE DAMAGE TO 3 STUDS AND WEST SIDE SIDING. THE EASTSIDE OF THE DWELLING RIDGE AND EAVE AREA ALSO HAVE DAMAGE. ONE SECTION AT THE SOUTH EAST CORNER WHERE THE FASCIA MEETS THE ROOF THERE ARE SIGNS OF DETACHMENT. TWO BROKEN WINDOWS REAR OF DWELLING. 3 STORAGE SHEDS WERE DAMAGED BY FIRE. TWO VEHICLES WERE DAMAGED BY FIRE. THE EASTSIDE WOOD FENCE WAS DAMAGED BY FIRE. ELECTRICAL DAMAGE TO THE WIRING SHEATHING LEAVING EXPOSED BARE WIRE AT THE ENCLOSED CARPORT AREA. ONE RECEPTACLE AND LIGHT FIXTURE WAS DAMAGED. THE DISCONNECT HAS TWO ADDED CIRCUITS ONE TO THE STORAGE SHED WHICH WAS DAMAGED BY FIRE. THE OTHER IS A NON METALLIC-SHEATHED CABLE NOT PROPERLY STRAP TO BUILDING. ENCLOSED CARPORT AREA HAS WIRING TO JUNCTION, LIGHT BOXES WITH UNAPPROVED WIRING METHOD UNSAFE, EXPOSED NONMETALLIC SHEATHED CABLE UNDER 96 INCHES IN CEILING INTERIOR OF DWELLING HAS LARGE AMOUNTS OF FECES IN BEDROOM AND BATHROOM. FRONT DECK IS DILAPIDATED MISSING DECK BOARDS UNSAFE. THE UNIT WAS CONDEMNED AND POSTED. DUE TO LACK OF POWER AND UNSANITARY CONDITIONS. SPECIAL INSTRUCTIONS ARE AS FOLLOWS: OWNER IS ALLOWED TO REPAIR, CLEAN DURING DAY TIME HOURS ONLY. LICENSE CONTRACTOR REQUIRED TO MAKE ALL REPAIRS SEE SIRE TO VIEW EMER CALLOUT CHECKLIST |
| 10/19/2009 | INSP - FOLLOW UP CODE ENFORCE | BWIESE | Approved | ROLL-OFF IN FRONT OF HOUSE FULL OF DEBRIS - STILL VACANT |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T09DV05476
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 09/22/2009 | NOTICE AND ORDER ISSUED |
| 09/24/2009 | NOTICE OF VIOLATION ISSUED |
| 06/04/2010 | VIOLATION CLOSED |
| 03/16/2010 | SEC LEIN PLACED ON PROPERTY IN THE AMOUNT OF ??? |
| 05/15/2012 | SEC LEIN RELEASED ON PROPERTY |
| 12/18/2009 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |