Description:

HOUSE FIRE CALL#0958000

Outstanding Inspections

Case Number: T09DV05476
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
10/21/2010 NPO(EL)-MAIN/PANEL/SUB/DISCONT DCOX Item closed
10/21/2010 NPO(EL)-WIRING/SWITCH/OUTLT/FX DCOX Item closed
10/21/2010 NPO - EXT. BUILDING MAINTENANC DCOX Item closed
10/21/2010 NPO - INT. BUILDING MAINTENANC DCOX Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T09DV05476
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/21/2009 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved VISUAL INSPECTION, FIRE DAMAGE TO ENCLOSED CARPORT, EXTERIOR SIDING WAS REMOVED FIRE DAMAGE TO 3 STUDS AND WEST SIDE SIDING. THE EASTSIDE OF THE DWELLING RIDGE AND EAVE AREA ALSO HAVE DAMAGE. ONE SECTION AT THE SOUTH EAST CORNER WHERE THE FASCIA MEETS THE ROOF THERE ARE SIGNS OF DETACHMENT. TWO BROKEN WINDOWS REAR OF DWELLING. 3 STORAGE SHEDS WERE DAMAGED BY FIRE. TWO VEHICLES WERE DAMAGED BY FIRE. THE EASTSIDE WOOD FENCE WAS DAMAGED BY FIRE. ELECTRICAL DAMAGE TO THE WIRING SHEATHING LEAVING EXPOSED BARE WIRE AT THE ENCLOSED CARPORT AREA. ONE RECEPTACLE AND LIGHT FIXTURE WAS DAMAGED. THE DISCONNECT HAS TWO ADDED CIRCUITS ONE TO THE STORAGE SHED WHICH WAS DAMAGED BY FIRE. THE OTHER IS A NON METALLIC-SHEATHED CABLE NOT PROPERLY STRAP TO BUILDING. ENCLOSED CARPORT AREA HAS WIRING TO JUNCTION, LIGHT BOXES WITH UNAPPROVED WIRING METHOD UNSAFE, EXPOSED NONMETALLIC SHEATHED CABLE UNDER 96 INCHES IN CEILING INTERIOR OF DWELLING HAS LARGE AMOUNTS OF FECES IN BEDROOM AND BATHROOM. FRONT DECK IS DILAPIDATED MISSING DECK BOARDS UNSAFE. THE UNIT WAS CONDEMNED AND POSTED. DUE TO LACK OF POWER AND UNSANITARY CONDITIONS. SPECIAL INSTRUCTIONS ARE AS FOLLOWS: OWNER IS ALLOWED TO REPAIR, CLEAN DURING DAY TIME HOURS ONLY. LICENSE CONTRACTOR REQUIRED TO MAKE ALL REPAIRS SEE SIRE TO VIEW EMER CALLOUT CHECKLIST
10/19/2009 INSP - FOLLOW UP CODE ENFORCE BWIESE Approved ROLL-OFF IN FRONT OF HOUSE FULL OF DEBRIS - STILL VACANT

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T09DV05476
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
09/22/2009 NOTICE AND ORDER ISSUED
09/24/2009 NOTICE OF VIOLATION ISSUED
06/04/2010 VIOLATION CLOSED
03/16/2010 SEC LEIN PLACED ON PROPERTY IN THE AMOUNT OF ???
05/15/2012 SEC LEIN RELEASED ON PROPERTY
12/18/2009 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS