Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

VOID

Type:

ILLEGAL DUMPING

Entered Date:

09/16/2009

Applicant:

CITY OF TUCSON

Description:

THIS IS A TEST FOR THE NOTICE PORTION.

Case Violations

Case Number: T09DV05347
Case Status: VOID
Case Description: ILLEGAL DUMPING
Total Violations: 8
Violation Date Code Statue
09/16/2009 T.C. Ch. 6, IBC adopted. IBC 110.1 USE AND OCCUPANCY. No building or structure shall be used or occupied, and no change in the existing occupancy classification of a building or structure or portion thereof shall be made until the building official has issued a certificate of occupancy therefore as provided herein.
09/16/2009 T.C. Ch. 6, IRC adopted. R311.3 LANDINGS AT EXTERIOR DOORS There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ¼ unit vertical in 12 units horizontal (2 percent).
09/16/2009 T.C. Ch. 6, IRC adopted. R311.7.1 STAIRWAY WIDTH Stairways shall not be less than 36 inches (914 mm) in clear width at all points above the permitted handrail height and below the required headroom height. Handrails shall not project more than 4.5 inches (114 mm) on either side of the stairway and the minimum clear width of the stairway at and below the handrail height, including treads and landings, shall not be less than 31.5 inches (787mm) where a handrail is installed on one side and 27 inches (698 mm) where handrails are provided on both sides.
09/16/2009 T.C. Ch. 6, IRC adopted. R311.5.3.1 RISER HEIGHT. The maximum riser height shall be 7 3/4 inches (196 mm). The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm).T.C. Ch. 6, IRC adopted. R311.7.5.1 RISER HEIGHT. The maximum riser height shall be 7 ¾ inches (196 mm). The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). Risers shall be vertical or sloped from the underside of the nosing of the tread above at an angle not more than 30 degrees from the vertical. Open risers are permitted provided that the opening between treads does not permit the passage of a 4-inch diameter sphere.
09/16/2009 T.C. Ch. 6, IRC adopted. R311.7.5.2 TREAD DEPTH. The minimum tread depth shall be 10 inches (254 mm). The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch.
09/16/2009 T.C. Ch. 6, IRC adopted. R311.7.8 HANDRAILS. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. R311.7.8.1 - Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm).
09/16/2009 T.C. Ch. 6, IRC adopted. R312.1 GUARDS. R312.1.1 - Where required. Guards shall be located along open-sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. Insect screening shall not be considered a guard. R312.1.2 - Height. Required guards at open-sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 inches high measured vertically above the adjacent walking surface, adjacent fixed seating or the line connecting the leading edges of the treads. R312.1.3 - Opening limitations. Required guards shall not have openings from the walking surface to the required guard height which allow passage of a sphere 4 inches in diameter.
09/16/2009 T.C. Ch. 6, IRC adopted. R312.1 GUARDS. Porches, balconies, ramps or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102mm) or more in diameter.

Outstanding Inspections

Case Number: T09DV05347
Case Status: VOID
Case Description: ILLEGAL DUMPING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
INSP - INITIAL CODE ENFORCMENT None Not Inspected
INSP - FOLLOW UP CODE ENFORCE None Not Inspected