Case: T09DV02270
Case Details
Entered Date:
04/27/2009
Applicant:
LA VOIE JOHN
Description:
NUMEROUS APPLIANCES IN FRONT YARD
Outstanding Inspections
Case Number: T09DV02270
Case Status: COMPLIAN
Case Description: REFUSE
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2009 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | HLOPEZ | Notice of violation | AMENDED NOV |
| 07/24/2009 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | HLOPEZ | Notice of violation | AMENDED NOV |
| 07/24/2009 | NPO(DL)-DILAPIDATED STRUCTURE | HLOPEZ | Notice of violation | AMENDED NOV |
| 07/24/2009 | NPO - REFUSE/TRASH/DEBRIS | HLOPEZ | Notice of violation | AMENDED NOV |
| 07/24/2009 | NPO - WEEDS/GRASSES | HLOPEZ | Notice of violation | AMENDED NOV |
Completed Inspections
Case Status: COMPLIAN
Case Number: T09DV02270
Case Description: REFUSE
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/07/2009 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | VIOLATIONS PRESENT/VACANT HCD INSPECTOR CONDUCTED ON-SITE INSPECTION REGARDING NUMEROUS APPLIANCES IN FRONT YARD. INSPECTION OF PROPERTY FOUND NO EVIDENCE OF LISTED COMPLIANT, HOWEVER THE FOLLOWING VIOLATIONS WERE PRESENT: (1) LARGE AMOUNTS OF TRASH, DEBRIS & REFUSE IN FRONT & BACK YARD. (2) LARGE AMOUNTS OF OVERGROWN VEGETATION THROUGH OUT FRONT & BACK YARD. (3) LARGE AMOUNTS OF DRIED OVERGROWN VEGETATION IN ALLEYWAY ALONG W/BROKEN WOODEN SLATS. (4) DETERIORATED & DILAPIDATED WOOD FENCING, SEVERAL SLATS WERE FOUND TO BE BROKEN, MISSING & SOME SECTION COMPLETELY GONE & OPEN TO ALLEY. SOME SECTION HAVE BEEN REPLACED WITH PLYWOOD TO FILL OPENINGS. PICTURES TAKEN, NOV TO BE ISSUED. |
| 07/16/2009 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | VIOLATIONS STILL PRESENT HCD INSPECTOR CONDUCTED COMPLIANCE ON NOV ISSUE REGARDING WOOD FENCING, ACCUM. OF REFUSE & VEGETATION & REMOVAL OF REFUSE FROM PROPERTY. HCD INSPEWCTOR WALKED PROPERTY TO VERIFY STRUCTURE WAS SECURED. SITE INSPECTION FOUND STRUCTURE IS SECURED & VACANT. INSPECTION OF ELECTRICAL DISCONNECT FOUND HAZARDOUS ELECTRICAL, DISCONNECT HAS BEEN MODIFIED IN A HAZARDOUIS MANNER (1) DOUBLE & TRIPPLE LUGGED ON LOAD SIDE (2) ADDITION OF ELECTRICAL CONDUCTOR W/OUT INSTALLATION INTO REQUIRED CONDUIT. (3) ADDITION OF S-TYPE FUSE & FUSE RECEPTACLE. WOOD FENCING & OVERGROWN VEGETATION IN ALLEY WAY HAS ALOS NOT BEEN ADDRESSED. NOV TO BE AMMENDED TO INCLUDE ELECTRICAL VIOLATIONS. PICTURES TAKEN |
Completed Activity Special Conditions
Case Description - REFUSE
Case Number - T09DV02270
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 06/08/2009 | CONTACTED BY PHONE |
| 07/24/2009 | CONTACTED BY MAILING |
| 07/24/2009 | NOTICE OF VIOLATION ISSUED |
| 02/07/2012 | VIOLATION CLOSED |
| 02/19/2010 | RESEARCH |