Case: T09DV01987
Case Details
Entered Date:
04/14/2009
Applicant:
CDTTT ENTERPRISES LLC
Description:
Raw sewage spilling into back of unit C. Pipes are stopped up inside Unit C. Water heater installed in the middle of the yard. Next to a storage buillding. Water heaters heats water for Apartments B and C and storage unit. Storage unit being modified into an apartment. Mice are living inside unit C and B. Refrigerator does not work in Unit C. No stove inside Unit C. Tenant has notified owners of problem. Active bee hive located in window frame in Unit B.
Outstanding Inspections
Case Number: T09DV01987
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 9
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/23/2009 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
10/23/2009 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Item closed | |
10/23/2009 | NPO(HC)-COOLING | RMENDOZA | Item closed | |
10/23/2009 | NPO(HC)-HEATING & VENTILATION | RMENDOZA | Item closed | |
10/23/2009 | NPO - INSECTS/PESTS | RMENDOZA | Item closed | |
10/23/2009 | NPO - SMOKE ALARMS | RMENDOZA | Item closed | |
10/23/2009 | NPO - EXT. BUILDING MAINTENANC | RMENDOZA | Item closed | |
10/23/2009 | NPO - WORK WITHOUT PERMIT | RMENDOZA | Item closed | |
10/23/2009 | NPO - INT. BUILDING MAINTENANC | RMENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T09DV01987
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2009 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | STORAGE SHED LOCATED BETWEEN UNITS A & B IS IN THE PROCESS OF BEING CONVERTED TO A DWELLING UNIT. SINK, TOILET, SHOWER AND ELECTRICAL ADDED WITHOUT PERMIT. EXPOSED ROMEX FROM MAIN PANEL ENTERING WALL TO SUPPLY POWER. PORCH ADDED TO REAR OF UNIT C. NOT ATTACHED OR CONSTRUCTED PROPERLY. HIGH POTENTIAL OF FAILURE OR COLLAPSE. UNITS B & C HAVE ADDED SINKS, TOILETS AND SHOWERS WITHOUT PERMIT WHICH INCLUDES ADDED EXTERIOR PLUMBING. ELECTRIC WATER HEATER INSTALLED WITHOUT PERMIT. WATER HEATER IS NOT FURHTER THAN THREE FEET FROM THE MAIN ELECTRICAL PANEL. UNDERGROUND PLUMBING ADDED TO SUPPLY HOT WATER TO UNITS B & C. UNIT B & C HAVE NO OPERATING WINDOWS. ALL WINDOWS ARE COVERED OR SEALED SHUT. UNIT LACKS OPERATIONAL SMOKE DETECTORS. UNITS LACK OPERATIONAL HEATING SYSTEMS. UNIT B COOLER PADS ARE DETERIORATED. EXCESSIVE RUST AND CORROSION PREVENT THE COOLER FROM OPERATING PROPERLY. EXPOSED ROMEX FROM MAIN ELECTRICAL PANEL TO STORAGE STRUCTURE. UNSAFE AND HAZARDOUS WIRING FROM MAIN ELECTRICAL PANEL TO REAR UNITS B & C. 50 AMP GE BREAKER NOT PROPERLY INSTALLED. WIRING FROM CIRCUIT IS NOT PROPERLY INSTALLED AND POSES A HAZARD AS THE WIRING IS NOT WITHIN CONDUIT, IS HANGING FROM PANEL WITH 5 FEET OF THE GROUND AND IS UNSAFELY ATTACHED TO THE STORAGE SHED. DOUBLE LUGGING WITHIN MAIN ELECTRICAL PANEL. DICONNECT PANELS AT UNITS B & C ARE NOT PROPERLY CONNECTED. EXPOSED ROMEX CONNECTED TO JUNCTION BOX SUPPLYING POWER TO UNIT C. EXTERIOR WATER LINES AT THE REAR OF UNIT C ARE LEAKING. DRAIN PIPE ON THE NORTH SIDE OF UNIT C IS NOT PROPERLY CONNECTED AND WASTE WATER IS BEING DRAINED TO THE GROUND. FLOOR TILES IN THE KITCHEN AND BATH IN UNITS B & C ARE PEELING. KITCHEN CABINET IN UNIT C BE IS DETERIORATED AND NOT PROPERLY SECURED. BEING HELD BY A 2X4. COUNTER COVERINGS ARE PEELING. HOLE IN THE CEILING DRYWALL LOCATED IN THE KITCHEN. BEE'S LOCATED ON THE NORTH SIDE OF UNIT B. NEAR THE BATHROOM WINDOW FRAMING. LARGE AMOUNT OF RODENT FECES UNDER THE KITCHEN SINK IN UNIT C. MAIN DOOR TO UNIT C LACKS AND OPERATIONAL DOOR HANDLE AND LOCKS. IS BEING LOCKED WITH WIRE EYED BOLTS AND A PADLOCK. MAIN DOOR TO UNIT C DOES NOT SEAL PROPERLY AND DOES NOT PROVIDE PROPER WEATHER PROTECTION AGAINTS THE ELEMENTS. WALL ON THE EAST SIDE OF UNIT C HAS BEEN CUT OUT FOR THE ADDITION OF PLUMBING. WALL IS COVERED WITH A PIECE OF PLYWOOD AND IS NOT PROPERLY SEALED. ROOF FOR UNITS B & C IS DETERIORATED. EDGES OF ROOF SHEATHING AND TRUSSES ARE ROTTED. |
10/23/2009 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | Unit remains vacant. Close case. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T09DV01987
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date | Name |
05/12/2009 | NOTICE OF VIOLATION ISSUED |
10/30/2009 | VIOLATION CLOSED |