03/04/2009
Applicant:
GEE RICHARD & LINDA TR
Description:
TWO METAL CARPORT BUILT WITHOUT PERMITS
Outstanding Inspections
Case Number: T09DV01075
Case Status: COURTCMP
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/20/2010 | NPO - WORK WITHOUT PERMIT | JVALDEZ | Item closed | |
09/01/2009 | LUC - ILLEGAL DWELLING UNIT | JVALDEZ | Follow-up inspection | |
09/01/2009 | LUC - VIOL OF SITE PLAN - COND | JVALDEZ | Follow-up inspection | |
09/01/2009 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | JVALDEZ | Follow-up inspection | |
09/01/2009 | NPO - JUNKED/INOP. VEHICLE(S) | JVALDEZ | Follow-up inspection |
Completed Inspections
Case Status: COURTCMP
Case Number: T09DV01075
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/05/2009 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Approved | SITE APPROVED ON 11-26-2001 INDICATES ALL STORAGE AND WORK IS TO BE DONE INSIDE THE PROPERTY. ADJACENT PROPERTIES OUR BEING USED FOR STORAGE OF VEHICLE'S AS A RESULT OF THE AUTO REPAIR BODY SHOP PANEL BOARD WAS ADDED WITHOUT PERMITS, THE PANEL BOARD IS POWERED BY DOUBLE LUGGING FROM THE MAIN DISCONNECT TO THE PANEL BOARD. THESE ARE UNSAFE AND UNAPPROVED WIRING METHODS. THE PANEL BOARD HAS 3 FEEDERS SUPPLYING POWER TO A RECEPTACLE, UNKNOWN SOURCE AND A RECREATIONAL VEHICLE RECEPTACLE. ROMEX WIRE HAS BEEN BURIED IN CERTAIN AREAS OF THE PROPERTY. THIS TYPE OF WIRE IS NOT RATED FOR UNDERGROUND USE. WIRING METHODS FROM THE PANEL BOARD TO EXTERIOR SOURCES IS AN UNAPPROVED WIRING METHOD AND UNSAFE RECREATIONAL VEHICLE ON PROPERTY IS BEING USED AS A DWELLING THE UNIT HAS A PERMANENT SEWER CONNECTION AND ILLEGAL ELECTRICAL CONNECTION. PER OUR CONVERSATION ON 2-26-2009 THE BUSINESS OWNER AND THE EMPLOYEE STATED TO ME THAT THEY ARE USING THE RECREATIONAL VEHICLE AS A DWELLING. METAL CARPORT WAS ATTACHED TO THE MAIN BUILDING DETACHED METAL CARPORT OVER 200 SQUARE FEET REAR OF PROPERTY CARPORTS INSTALL WITHOUT PERMITS |
09/01/2009 | INSP - FOLLOW UP CODE ENFORCE | JVALDEZ | Approved | PERMIT T09CM02281 ISSUED 08/27/2009 COMPLIANCE PERMIT FOR RAMADA/CARPORT, PER INSPECTOR COMMENTS ON; T09DV01075 PERMIT EXPIRES ON 02/23/2010 FOLLOW INS WILL BE SCHEDULED FOR EXPIRATION DATE |
Completed Activity Special Conditions
Case Description - WORK WITHOUT PERMITS-COMMERCL
Case Number - T09DV01075
Case Status: COURTCMP
Total Completed Case Activity Conditions: 8
Date | Name |
03/11/2009 | CONTACTED BY MAILING |
03/09/2010 | CERTIFIED RECEIPT CARD |
03/05/2009 | NOTICE OF VIOLATION ISSUED |
02/26/2010 | CITATION ISSUED |
08/23/2010 | VIOLATION CLOSED |
06/28/2010 | COURT HEARING INFO |
03/17/2010 | REINSPECTION FEE - FIRST |
05/13/2010 | REINSP FEE - PAID IN FULL |