Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

11/03/2008

Applicant:

WON YOUNG H & SO H JT/RS

Description:

FULL FIRE INSPECTION EMBASSY TIRE AND WHEEL CO.

Completed Inspections

Case Status: COMPLETE
Case Number: T08FR04129
Case Description: INSPECTION
Total Completed Inspections - 7
End Date Description Inspector Results Comments
11/03/2008 VIOL - FIRE SERVICE FEATURES JLOYA Approved 505.1 Address numbers. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. Address numbers shall be in accordance with Pima County address display requirements.
11/03/2008 VIOL - BUILDING SVCS & SYSTEMS JLOYA Approved TFC 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes.
11/03/2008 VIOL - BUILDING SVCS & SYSTEMS JLOYA Approved TFC 605.5 - Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. _____ Replace with approved power strip.
11/03/2008 VIOL - PRECAUTION AGAINST FIRE JLOYA Approved TFC 315.2.1 - Ceiling clearance. Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings
11/03/2008 VIOL - PRECAUTION AGAINST FIRE JLOYA Approved TFC 304.1 Waste accumulation prohibited Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. ____ CLEAR EMOTY CARDBOARD BOXES IN BACK.
11/03/2008 INSP - FULL JLOYA Approved FULL FIRE INSPECTION CONDUCTED 10-31-08
11/21/2008 INSP - REINSPECTION JLOYA Approved All violations abated.