Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

09/11/2008

Applicant:

BETA DELTA BLDG CORP

Description:

FULL FIRE INSPECTION

Completed Inspections

Case Status: COMPLETE
Case Number: T08FR02752
Case Description: INSPECTION
Total Completed Inspections - 7
End Date Description Inspector Results Comments
09/11/2008 VIOL - FIRE PROTECTION SYSTEMS JVINCENT Approved 901.6.1 Standards. Fire protection systems shall be inspected, tested and maintained in accordance with the referenced standards listed in Table 901.6.1. ____Repair deficiencies in cooking system/hood report. ____Commercial cooking extinguishing system needs to be tied into alarm panel.
09/11/2008 INSP - FULL JVINCENT Approved FULL FIRE INSPECTION
09/11/2008 VIOL - EMERGENCY PLAN/PREPARE JVINCENT Approved 405.2 Frequency. Required emergency evacuation drills shall be held at the intervals specified in Table 405.2 or more frequently where necessary to familiarize all occupants with the drill procedure. ____Four Evacuation drills required annually. Keep records on-site.
09/11/2008 VIOL - FIRE PROTECTION SYSTEMS JVINCENT Approved 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. ____Fire Alarm System needs an annual inspection. Provide documentation. ____Test every smoke detector and log. Provide documention upon re-inspection.
09/11/2008 VIOL - MEANS OF EGRESS JVINCENT Approved 1027.3 Exit sign illumination. 1027.4 Power source. ____Repair all illuminated Exit signs. ____Front/Main door. ____East exit, 2nd floor. ____"Dungeon"
09/11/2008 VIOL - MEANS OF EGRESS JVINCENT Approved 1027.5 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises’ electrical supply. In the event of power supply failure, illumination shall be automatically provided from an emergency system for the following occupancies where such occupancies require two or more means of egress. ____Repair all illuminated Exit signs: ____Repair emergency ligting unit near room #20.
09/11/2008 VIOL - BUILDING SVCS & SYSTEMS JVINCENT Approved 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the code official responsible for enforcement of the ICC Electrical Code. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. ____Coverplate needed for all exposed electrical. ____"Freddys room" ____West entry hall, above door.