Case: T08FR01359
Case Details
Entered Date:
05/29/2008
Applicant:
VESTERGOM BROADWAY LLC
Description:
Full Inspection
Outstanding Inspections
Case Number: T08FR01359
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 11
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/29/2008 | VIOL - PRECAUTION AGAINST FIRE | TKNAPP | Correction Required | 315.2.3 Storage shall not be allowed to accumlate in electrical room. |
05/29/2008 | VIOL - BUILDING SVCS & SYSTEMS | TKNAPP | Correction Required | 605.1 Power cord to coffee machine shall be repaired. |
05/29/2008 | VIOL - BUILDING SVCS & SYSTEMS | TKNAPP | Correction Required | 605.3 Working space at electrical panels in training room shall be provided. |
05/29/2008 | VIOL - BUILDING SVCS & SYSTEMS | TKNAPP | Correction Required | 605.6 Junction box at walk in cooler shall be provided with a cover. |
05/29/2008 | VIOL - FIRE RESIST.RATED CONST | TKNAPP | Correction Required | 703.1 Missing ceiling tiles at kitchen shall be replaced. |
05/29/2008 | VIOL - MEANS OF EGRESS | TKNAPP | Correction Required | 1008.1.8.3 Exit doors on SW corner shall have "Must remain unlocked" sign. |
05/29/2008 | VIOL - MEANS OF EGRESS | TKNAPP | Correction Required | 1027.3 Exit sign at SW door shall be repaired. |
05/29/2008 | VIOL - MEANS OF EGRESS | TKNAPP | Correction Required | 1027.3 The exit sign at the NW exit shall be repaired. |
05/29/2008 | VIOL - MEANS OF EGRESS | TKNAPP | Correction Required | 1028.4 / 1011.1 Exit sign shall be installed at south dining area exit. |
05/29/2008 | VIOL - COMPRESSED GASES | TKNAPP | Correction Required | 3003.5 Compressed gas cylinders at SW corner shall be secured. |
05/29/2008 | VIOL - COMPRESSED GASES | TKNAPP | Correction Required | 3003.5 Compressed gas cylinders shall be secured by liquor room. |
Completed Inspections
Case Status: COMPLETE
Case Number: T08FR01359
Case Description: INSPECTION
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/12/2008 | INSP - FULL | TKNAPP | Approved |