Outstanding Inspections

Case Number: T08FR01179
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 10
End Date Description Inspector Results Comments
05/09/2008 VIOL - FIRE SERVICE FEATURES JBURGE Correction Required TFC 505.1- Address numbers. Address numbers shall be in accordance with Pima County address display requirements. NOTE: 15 inch numbers required.
05/09/2008 VIOL - BUILDING SVCS & SYSTEMS JBURGE Correction Required TFC 605.4- Multiplug adapters. Remove the cube adapter located in the managers office on the south wall.
05/09/2008 VIOL - BUILDING SVCS & SYSTEMS JBURGE Correction Required TFC 605.5- Extension cords. Remove the orange extension cord located in the manager's office. NOTE: Replace the extension cord and cube adapter with a fused power strip.
05/09/2008 VIOL - BUILDING SVCS & SYSTEMS JBURGE Correction Required TFC 605.6- Unapproved conditions. All open spaces in the electrical panels located in the pin set area shall have an approved cover.
05/09/2008 VIOL - FIRE PROTECTION SYSTEMS JBURGE Correction Required TFC 903.3.3- Obstructed locations. An automatic sprinkler system head shall be installed inside the beer frige for required coverage.
05/09/2008 VIOL - MEANS OF EGRESS JBURGE Correction Required TFC 1008.1.8- Door operations. Remove the door knob from the southeast door in the nursery.
05/09/2008 VIOL - MEANS OF EGRESS JBURGE Correction Required TFC 1008.1.8.4- Bolt locks. Remove the surface bolt from the door located in the kitchen.
05/09/2008 VIOL - MEANS OF EGRESS JBURGE Correction Required TFC 1027.3- Exit sign illumination. All exit signs shall be fully illuminated. NOTE: Exit sign locations; main entrance, sales counter, northwest exit doors, southwest exit doors, southeast exit door and northeast exit door.
05/09/2008 VIOL - HAZARDOUS MATERIALS,GEN JBURGE Correction Required TFC 2703.3.1.4- Responsibility for cleanup. Clean and properly dispose of the spilled oil and contaminated soil on the south side of the building by the maintenance room.
05/09/2008 VIOL - COMPRESSED GASES JBURGE Correction Required TFC 3003.5.3- Securing compressed gas containers, cylinders and tanks. Secure the compressed gas cylinder located in the kitchen.

Completed Inspections

Case Status: COMPLETE
Case Number: T08FR01179
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
08/27/2008 INSP - FULL JBURGE Approved All noted Tucson Fire Code violations have been corrected.