Status:

COMPLETE

Type:

INSPECTION

Entered Date:

04/11/2008

Applicant:

HALLAQ ISSA Y & HENRIETTA Z JT/RS

Description:

FULL FIRE INSPECTION.

Completed Inspections

Case Status: COMPLETE
Case Number: T08FR00919
Case Description: INSPECTION
Total Completed Inspections - 5
End Date Description Inspector Results Comments
04/11/2008 VIOL - MEANS OF EGRESS JVINCENT Approved TFC 1008.1.2 1) STAIRWELL SECURITY DOORS NEED TO SWING IN THE DIRECTION OF EGRESS TRAVEL.
04/11/2008 VIOL - MEANS OF EGRESS JVINCENT Approved TFC 1008.1.8.3 1) REMOVE DOUBLE KEYED DEADBOLTS FROM STAIRWELL SECURITY GATES.
04/11/2008 VIOL - FIRE RESIST.RATED CONST JVINCENT Approved TFC 703.1 1) REPLACE MISSING CEILING TILE FROM TELEPHONE CLOSET ON 2ND FLOOR.
04/11/2008 VIOL - MEANS OF EGRESS JVINCENT Approved TFC 1028.8 1) remove all other locking devices from doors equipped with panic hardware. main door 1st floor door labeled 235-245, 2nd floor
05/07/2008 INSP - FULL JVINCENT Approved 3YR FIRE INSPECTION CYCLE APPROVED.