Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T08FR00797
Case Details
Entered Date:
03/26/2008
Applicant:
HOM HOWARD & JANET LIVING TR
Description:
Full Inspection GENESIS Family Hair Styling Building Rep: Alma Venzuela Phone # 792-4944
Outstanding Inspections
Case Number: T08FR00797
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/26/2008 | INSP - FULL | JLONGO | Correction Required | Full Inspection Completed. Please correct the following Tucson Fire Code Violations |
03/26/2008 | VIOL - BUILDING SVCS & SYSTEMS | JLONGO | Correction Required | 605.4 Multiplug adapters Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC electrical code shall be prohibited. ____ Remove all mutiplug cube adapters and/or replace with approved fused power strips. 605.5 Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. ____ Remove all extension cords and/or replace with approved fused power strips. |
03/26/2008 | VIOL - FIRE PROTECTION SYSTEMS | JLONGO | Correction Required | 906.7 Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. ____ All Protable Fire Extinguishers shall be removed or properly mounted. Your Fire Extinguishers shall not be mounted higher then 4 & 1/2 feet or lower then 4inches from the ground ________________________________________________ (Joseph P. Longo, Inspector, Tucson Fire Department) I, ______________________ have received a copy of this inspection report. (Building Representative) ______________________________ (Captain) Full inspection done by Inspector Joseph P. Longo Re-inspection scheduled on or after ___/___/___ Call Inspector Longo at 235-4262 or 791-4502, if you have any further questions. Thank you. Re-inspection passed: ______________________ Joseph P. Longo |