Case: T08DV09451
Case Details
Entered Date:
10/02/2008
Applicant:
WINGED FOOT INVESTMENT SERVICES LLLP
Description:
A/C NOT WORKING, HOLES IN TRAILER, MISC OTHER ISSU
Outstanding Inspections
Case Number: T08DV09451
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 8
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2008 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
| 12/11/2008 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Item closed | |
| 12/11/2008 | NPO(HC)-COOLING | RMENDOZA | Item closed | |
| 12/11/2008 | NPO - INSECTS/PESTS | RMENDOZA | Item closed | |
| 12/11/2008 | NPO - SMOKE ALARMS | RMENDOZA | Item closed | |
| 12/11/2008 | NPO - EXT. BUILDING MAINTENANC | RMENDOZA | Item closed | |
| 12/11/2008 | NPO - WORK WITHOUT PERMIT | RMENDOZA | Item closed | |
| 12/11/2008 | NPO - INT. BUILDING MAINTENANC | RMENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T08DV09451
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/10/2008 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | MICE INFESTATION. STEPS. EXPOSED ROMEX. HOLES IN WALLS. BATHROOM LACK FLOOR. WATER HEATER IN BEDROOM. FURNACE INOP. UNIT SHUT DOWN & VACATED DUE TO UNSAFE & UNSANITARY CONDITIONS. NOV'S SIGNED BY PROPERTY MANAGER JUDY. [INSPECTION NOTES] WATER HEATER INSTALLED IN REAR BEDROOM WITHOUT PERMITS. COOLER SWITCH INSTALLED IN THE HALLWAY. EXPOSED ROMEX ENTERING COOLER PLENUM. UNIT LACKS OPERATIONAL SMOKE DETECTORS. FURNACE IS INOPERABLE. CEILING IN THE HALLWAY AT COOLER VENT IS DAMAGED DUE TO LEAKING COOLER. OUTLET AT THE WEST WALL LIVING ROOM AREA IS NOT PROPERLY SEALED. EXPOSED ROMEX IN THE HALLWAY AT COOLER SWITCH. WIRING ENTERING COOLER PLENUM. WATER INSTALLED IN THE REAR BEDROOM. LACKS COLD WATER SHUT OFF. FLUE VENT PIPE NOT PROPERLY INSTALLED. HOT WATER LINE LEAKING. WATER CLOSET FLOOR IS EXTREMELY DETERIORATED. LARGE HOLES IN THE FLOOR NOT PROPERLY SEALED EXPOSING INTERIOR TO THE ELEMENTS. CEILING IN THE HALLWAY AT COOLER VENT IS DETERIORATED AND SAGGING DUE TO WATER DAMAGE. FLOOR IS SEPARATING FROM THE WALL ALONG THE WEST SIDE OF THE UNIT. HALLWAY BEDROOM CLOSET WALLS ARE NOT PROPERLY SEALED. WATER LINE AND DRAIN/VENT PIPES RUN THROUGH THE CLOSET. BATHTUB JOINTS ARE NOT PROPERLY SEALED. BATHROOM FLOOR IS EXTREMELY DETERIORATED. MOST OF THE FLOOR IS MISSING EXPOSING THE UNDERNEATH OF THE UNIT. BATHROOM IS UNSAFE FOR USE. UNIT IS INFESTED WITH RODENTS. EVIDENCE OF RODENT DROPPINGS THROUGHOUT THE KITCHEN AND LIVING ROOM. HALLWAY DOOR IS EXTREMELY DETERIORATED. BOTOOM AREA OF THE DOOR IS MISSING. DOES NOT PROVIDE PROPER SHELTER TO OCCUPANTS AGAINST THE ELEMENTS. STAIRWAY AT FRONT DOOR IS DETERIORATED AND IS NOT CAPABLE OF SUPPORTING A LOAD. STAIRWAY LACKS PROPER HANDRAILS. |
| 12/11/2008 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | UNIT HAS BEEN REMOVED. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T08DV09451
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 10/16/2008 | CONTACTED BY MAILING |
| 10/16/2008 | NOTICE OF VIOLATION ISSUED |
| 12/18/2008 | VIOLATION CLOSED |