Case Details

Status:

REFERRED

Type:

RES: MINIMUM HOUSING

Entered Date:

10/01/2008

Applicant:

ALBERTO MURGUIA

Description:

SUNSET RANCH MH PROJECT: SPACE #2

Case Violations

Case Number: T08DV09329
Case Status: REFERRED
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
Violation Date Code Statue
05/25/2010 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T08DV09329
Case Status: REFERRED
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
09/22/2008 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved **BUILDING** -BROKEN WINDOW (LACKS WEATHER PROTECTIONS) -AWNING HAS NON APPROVED SUPPORTS, NOTCHING AND OVER SPANING; 2 X 4 -STAIRS LACKING RAILS **ELECTRICAL** -ENERGIZED WIRES EXPOSED ON EXTERIOR ARE NOT ATTACHED TO STRUCTURE AND NOT CAPPED OFF -SERVICE PANEL DEAD PLATE NOT LABELED PROPERLY -ADDED CIRCUIT; AZ BOX; 2 15 AMP FUSES **PLUMBING** -WATER HEATER CLOSET DOOR MISSING -PIPING (GAS?) KINKED **REMARKS** -LACKING PROPER ADDRESS; CLARIFICATION
09/22/2008 NPO(PL)-PLUMBING SYSTEM & FX CBIGMAN Item closed
09/22/2008 NPO(PL)-GAS SUPPLY/CONNECT CBIGMAN Item closed
12/02/2008 NPO(EL)-WIRING/SWITCH/OUTLT/FX CBIGMAN Notice of violation
12/02/2008 NPO(PL)-WATER HEATERS CBIGMAN Notice of violation
12/02/2008 NPO - EXT. BUILDING MAINTENANC CBIGMAN Notice of violation
12/02/2009 NPO(EL)-MAIN/PANEL/SUB/DISCONT CBIGMAN Notice of violation

Completed Inspections

Case Status: REFERRED
Case Number: T08DV09329
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/26/2009 INSP - FOLLOW UP CODE ENFORCE CBIGMAN Approved STAIR HANDRAILS ARE NOT CAPABLE OF SUPPORTING LOAD, WINDOW STILL BROKEN. PERMTI ON FILE BUT THE INSPECTIONS HAVE BEEN CALLED IN

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T08DV09329
Case Status: REFERRED
Total Completed Case Activity Conditions: 6
Date Name
05/12/2009 CONTACTED BY PHONE
12/02/2008 CONTACTED BY MAILING
12/02/2008 NOTICE OF VIOLATION ISSUED
10/28/2009 CITATION ISSUED
05/25/2010 VIOLATION CLOSED
02/25/2009 RESEARCH