Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

08/15/2008

Applicant:

MADDOX RICHARD T & CHRISTINE ANN JT/RS

Description:

ELECTRICAL SERVICE UPGRADE REQUIRED

Outstanding Inspections

Case Number: T08DV07130
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
10/09/2008 NPO(EL)-MAIN/PANEL/SUB/DISCONT ASMITH Item closed
10/09/2008 NPO(EL)-WIRING/SWITCH/OUTLT/FX ASMITH Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T08DV07130
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/15/2008 INSP - INITIAL CODE ENFORCMENT DCOX Approved Tucson Fire was called to the residence by the owner who discovered a "hot-spot" in an interior wall. After disconnecting the main electrical service to the home is was discovered areas of the home were still energized. TEPCO and myself were called to the home by TFD to evaluate the problem. I discovered the home still had the original 60 amp service panel and that there were some modificatons that were most likely done w/o permit and inspections. TEPCO representative disconnected the hot lead at the service panel and the home was still energized with a slight amount of voltage. The TRPCO tech cut the neutral feed from the pole and encountered voltage feeding throught that wire, indicating a possibility that the wires leading from the pole may be in contact with each other at some point between the pole and the service entrance to the home. I asked the TEPCO rep to disconn. the feed at the pole and directed the owner/occupant to retain a licensed electrical contractor to upgrade the service and evaluate for any further problems within the home. The owner stated she had another place to stay until repairs were completed.
10/09/2008 INSP - FOLLOW UP CODE ENFORCE ASMITH Approved ELECTRICAL UPGRADE HAS BEEN COMPLETED. CLOSE CASE. PERMIT # T08EL01866 9-26-08.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T08DV07130
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
08/15/2008 CONTACTED BY PHONE
10/09/2008 VIOLATION CLOSED
08/15/2008 CALLBACK

Documents

File Name Document Type  
DAMAGE REPORT 08-15-08 DOCUMENTS VIEW