Case Details

Status:

COURTCMP

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

02/25/2008

Applicant:

CLARK CHRISTINA A

Description:

APT B FIRE EXTINGUISHERS OUTDATED, ELECTRICAL WIRING PROTRUDING FROM GROUND, ISSUES WITH THERMOSTAT - DIFFICULT TO TURN ON AND OFF, ONLY ONE EXIT / 2 FRONT WINDOW ENCLOSED WITH BARS.

Outstanding Inspections

Case Number: T08DV01567
Case Status: COURTCMP
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
05/19/2008 NPO(EL)-WIRING/SWITCH/OUTLT/FX HLOPEZ Item closed
05/19/2008 NPO(PL)-PLUMBING SYSTEM & FX HLOPEZ Item closed
05/19/2008 NPO - EXT. BUILDING MAINTENANC HLOPEZ Item closed
08/21/2008 NPO - WORK WITHOUT PERMIT HLOPEZ Item closed

Completed Inspections

Case Status: COURTCMP
Case Number: T08DV01567
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/26/2008 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VISITED SITE FOR INITIAL INSPECTION ON 2-26-08. MADE CONTACT WITH TENANT. VIOLATIONS PRESENT & ARE AS FOLLOWS. TENANT WENT OVER ELECTRICAL WIRING PROTRUDING AROUND & ALONG EXTERIOR. INSPECITON OF COMPLIANT IS INVALID, TENANT THOUGHT CABLE WIRE & TELEPHONE WIRE WERE ENERGIZED WITH 110 CURRENT. PLUMBING ISSUES 1) ELECTRIC HOT WATER HEATERS LACKING ENCLOSURE & 1 ENCLOSURE DILAPIDATED, NO LONGER ATTACHED TO WALL 2) APPEARS COPPER LINE WERE INSTALLED SOME TIME BACK & ARE LACKING WEATHER PROTECTION. 3) TUB ENAMEL DETERIORATED & EXPOSED METAL ARE RUSTING THROUGH EXTERIOR ELECTRICAL 1) LAUNDRY AREA, ELECTRIC RECEPTACLES LAKCING REQUIRED WEATHER PROTECTION COVERS 2) ELECTRICAL HOT WATER HEATERS CONNECTED BY USE OF APPLIANCE CORD & NOT HARD WIRED. NO EVIDENCE OF MOLD ISSUES WERE PRESENT, TENANT STATED STATE INSPECTION BY CPS INSPECTOR STATED MOLD WAS PRESENT INTERIOR ELECTRICAL SYS INSPECTION OF INTERIOR ELECTRICAL SYSTEM WITH TEST EQUIPMENT. 1 WALL CONTROL SWITCH WAS NOT WORKING IN EAST BEDROOM & 1 RECEPTACLE NOT SECURED TO WALL IN LIVING ROOM. INSPECTION OF T-STAT FOR HEATING FOUND NO ISSUES WITH OPERATION, T-STAT WAS TESTED SEVERAL TIMES & ELECT FURNACE FIRED UP. PICTURES TAKEN. TENANT MOVING OUT NEXT WK. [THESE NOTES ALSO AVAILABLE IN SIRE]
08/20/2008 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VISITED SITE, APPEARS VIOLATION HAS BEEN ABATED TO CODE REQUIREMENTS, PP TO BE CHECKED FOR PLUMBING FINAL, COURT SCHEDULED FOR 8-21-08 11:00AM. PICTURES TAKEN.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T08DV01567
Case Status: COURTCMP
Total Completed Case Activity Conditions: 6
Date Name
04/10/2008 CONTACTED BY PHONE
03/17/2008 CONTACTED BY MAILING
03/12/2008 NOTICE OF VIOLATION ISSUED
06/17/2008 CITATION ISSUED
09/09/2008 VIOLATION CLOSED
09/09/2008 COURT HEARING INFO

Documents

File Name Document Type  
INSPECTION NOTES 02-26-08 DOCUMENTS VIEW
NOV OWNER 03-13-08 DOCUMENTS VIEW
CITATION 6772257 CHRISTINA A CLARK 06-18-08 DOCUMENTS VIEW
COURT DOCUMENT 08-21-08 DOCUMENTS VIEW
None IMAGES VIEW