Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T08DV01160
Case Details
Entered Date:
02/15/2008
Applicant:
MENLO PARK SHOPPING CENTER COMPANY
Description:
COMMUNICATIONS TFD REQUESTING ELECTRICAL INSPECTOR AT FOOD CITY FOR WATER LEAK FROM ROOF INTO AN ELECTRICAL BOX. ALARM # 08-10081, TFD NO LONGER ON SITE.
Outstanding Inspections
Case Number: T08DV01160
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected | ||
02/15/2008 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | JORTA | Item closed | |
02/15/2008 | NPO(PL)-PLUMBING SYSTEM & FX | JORTA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T08DV01160
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2008 | INSP - INITIAL CODE ENFORCMENT | JORTA | Approved | ARRIVED AT 10:00 AM AND MET WITH FIRE INSPECTOR JOHN BIEG AND STORE MANAGER ESPERANZA CONSTANTE. SURVEYED THE SITUATION AND DESCRIBED THE VIOLATION TO FIRE AND MANAGEMENT. THE FIRE INSPECTOR SAID THAT HE WILL INCLUDE ALL OF MY FINDINGS INTO HIS REPORT. MY FINDINGS AND CORRECTIONS WERE: 1. A WATER LEAK AT ROOF(RAIN) LEAKING DOWN ON SURFACE OF VERTICAL WALL AND ENTERING ELECTRICAL BOXE AND PANEL BOARD. THE WATER SATURATION IS AT THE BASE OF THE ENCLOSURE. 2. SEVERAL PANEL BOARDS HAVE MISSING FILLER PLATES. 3.VARIOUS CLEANERS, BOTTLES AND MISCELLANEOUS ITEMS ARE BEING PLACED ON TOP OF THE ELECTRICAL ENCLOSURE. 4. MOPS, BUCKETS, BROOMS AND FLOOR MACHINE ARE BEING STORED IN FRONT OF ALL THE ELECTRICAL PANEL AND SIMILAR EQUIPMENT. THE FIRE INSPECTOR AND MYSELF SPOKE TO ESPERANZA(MANAGER) AND TOLD HER THE TFD WILL GIVE SO MANY DAYS(?) TO MAKE SURE THE FOLLOWING REPAIR. A) PATCH THE ROOF IMMEDIATELY B) OPEN ELECTRICAL BOXES AND PANEL BOARDS AND INSPECT AND DRUG OUT COMPONENTS WHERE APPLICABLE C) INSTALL FILLER PLATES D) DO NOT USE TOP OF ELECTRICA ENCLOSURE FOR ANY TYPE OF STORAGE E) MAINTAIN A 4 FT WORKING CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT AND TGE SERVICE EQUIPMENT. NO VOLTAGE LEAKAGE WAS DETECTED AND THERE COULD BE A POSSIBILITY OF FOREIGN PIPING IN THE DEDICATED SPACE ABOVE THE SWITCHBOARD. LEFT THE WITH THE FIRE INSPECTOR STATING THAT HE WILL BE DOING THE COMPLETE WRITE UP. COMPLETE 11:00 AM. CASE CLOSED |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T08DV01160
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date | Name |
03/03/2008 | VIOLATION CLOSED |
06/12/2008 | 8-5 CITY COMM EMERGENCY |