Case Details

Status:

REFERRED

Type:

RES: MINIMUM HOUSING

Entered Date:

02/07/2008

Applicant:

KHAN IJAZ

Description:

UNINHABITABLE LIVING CONDITIONS. NO HEAT OR HOT WATER. REFER TO PREVIOUS CASE T03DV00607.

Outstanding Inspections

Case Number: T08DV00988
Case Status: REFERRED
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 34
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
02/07/2008 INSP - INITIAL CODE ENFORCMENT JHURD Approved UNIT A DIRECTLY INTO CITATION: NO N/O/V ISSUED. DWELLING LACKS NATURAL GAS DUE TO NON PAYMENT BY OWNER. OFF SINCE NOV. 07 DWELLING LACKS HEAT. DWELLING LACKS HOT WATER. DWELLING SHOWS ELECTRICAL HAZARDS IN CONVENIENCE OUTLETS, SPARKING WHEN MOVED, FLICKERING WHEN TESTED. VISITED SITE: SEVERAL ISSUES, LIVING ROOM: 1- FRONT DOOR HINGE BROKEN 2- FRONT DOOR, DOOR JAMB BROKEN, CAN NOT SECURE DOOR 3- CAN SEE COMPLETELY THROUGH INTERIOR WALL TO EXTERIOR DOOR, OCCUPANT USING MASKING TAPE TO TRY AND SEAL FROM EXTERIOR ELEMENTS. 4- FRONT DOOR PANELS BROKEN/CRACKED DO NOT SEAL AS INTENDED, OCCUPANT USING MASKING TAPE TO TRY AND SEAL FROM EXTERIOR ELEMENTS. 5- LIVING ROOM WINDOW CRACKED. 6- LIVING ROOM WINDOW DOES NOT PROPERLY SIT IN TRACK, ALLOWS FOR GAP AT TOP RIGHT HAND SECTION. 7- CONVENIENCE OUTLET ON SOUTH WALL DOES NOT OPERATE, TEST SHOWS LIGHT FLICKERING, SHORT. BEDROOM (1) NORTH SIDE: 8- BEDROOM DOOR JAMB BROKEN CAN NOT SECURE DOOR. 9- BEDROOM DOOR HANDLE BROKEN, MISSING REQUIRED HARDWARE. 10- CONVENIENCE OULET LOCATED BEHIND DOOR, BADLY BURNT, SPARKS WHEN MOVED. SMELL OF ELECTRICAL WIRING BURNING/BURNT. 11- ROOF LEAK. 12- CEILING REPAIR LEAVES GAPS, NOT PROPERLY INSTALLED, DOES NOT SEAL AS INTENDED. 13- HALL: HEATER DOES NOT OPERATE, VERY DIRTY, LACKS ANY AND ALL PROPER MAINTENANCE. BATHROOM: 14- NEW SEWER LINES ADDED, W.O.P 15- OPEN SEWER LINE UNDER VANITY SINK. 16- NEW SEWER LINE RAN THROUGH WALL TO EXTERIOR SEWER, WALL NEVER REPAIRED UTILIZING TOWELS TO PLUG HOLE FROM EXTERIOR ELEMENTS. GOES DIRECTLY THROUGH. 17- TUB/SHOWER, FRAMING DETERIORATED DUE TO WATER. 18- TUB/SHOWER CAULK SEALANT CRACKED, SEPERATING, MISSING IN AREAS, ALLOWING FOR WATER TO ENTER BEHIND WALL COVERINGS AND DETERIORATE STRUCTURE WALLS. 19- CEILING SHOWS EVIDENCE OF ROOF LEAK. 20- WALL BEHIND DOOR DETERIORATED WOOD, LACKS PROPER COVERING FOR SEALANT. 20- BATHROOM VANITY SINK DOES NOT OPERATE AS INTENDED, ONLY COLD SIDE OPERATES. HALLWAY: 21- HAZARDOUSLY UTILIZING EXTENSION CORDS DUE TO CONVENIENCE OUTLET NOT OPERATING AS INTENDED. 21- COOLER OPENING LACKS DIRECTIONAL COVERING, HOLES HAS TO BE PLUGED BY TOWELS TO BLOCK OPENING FROM ALL EXTERIOR ELEMENTS. 21- OPEN AND EXPOSED ELECTRICAL WIRING HANGING FROM CEILING. BEDROOM (2) SOUTH SIDE 22- BEDROOM DOOR HINGES BROKEN DOES NOT OPERATE AS INTENDED. 23- DEADBOLT LOCK INSTALLED ON BEDROOM DOOR. 24- UTILIZING SPACE HEATER FOR HEAT DUE TO CONDITION OF HEATER, ALSO DWELLING LACKS GAS TO SUPPLY HEATER. 25- CONVENIENCE OUTLET STICKS OUT OF WALL, NOT PROPERLY SECURED. KITCHEN: 26- KITCHEN DOOR, DOES DOES NOT PROPERLY SEAL AS INTENDED, UTILIZING TOWELS, TAPE TO SEAL FROM ALL EXTERIOR ELEMENTS. DOOR LACKS ALL REQUIRED HARDWARE. 27- KITCHEN FAUCET DOES NOT OPERATE AS INTENDED ONLY HOT WATER SIDE OPERATES, COUNTERTOP BROKEN HAS HOLE IN RIGHT HAND CORNER. ALLOWS FOR WATER TO RUN OFF IN TO STRUCTURE. 28- REFRIGERATOR, FRESH FOOD DOOR BROKEN DOES NOT SEAL AS INTENDED, ALLOWS FOR ALL COLD AIR TO ESCAPE, CAN NOT KEEP FOOD. OCCUPANT TRYING TO USE MASKING TAPE TO SEAL AND KEEP CLOSED. 29- FREEZER DOOR LACKS FREEZER DOOR HANDLE. 30- MOUSE TRAP DUE TO MOUSE INFESTATION, MOUSE DROPPING ON FLOOR. EXTERIOR: 31- WINDOW WOOD FRAMING DETERIORATED DUE TO EXTERIOR ELEMENTS, LACK OF PROTECTIVE TREATMENT, DOES NOT PROPERLY SEAL WINDOW FRAMES. 32- SEWER LINE LOCATED ON SOUTH SIDE OF STRUCTURE LEAKS IN 4 DIFFERENT AREAS, DIRECTLY ONTO GROUND, ALSO W.O.P NOT INSTALLED PROPERLY WILL NOT PASS CODE INSPECTION. 33- WOOD FACIA BOARDS LACK EXTERIOR PROTECTIVE TREATMENT, DETERIORATING. 34- ELECTRICAL, NEW SERVICE INSTALLED, NO PERMIT. NEW EXTERIOR LINE INSTALLED FOR EXTERIOR CONVENIENCE OUTLET. 35- SHOWS EXTERIOR SIDE OF WHERE HOLES HAS TO BE BLOCKED BY TOWELS FROM EXTERIOR ELEMENTS. 36- HOT WATER TANK ENCLOSER NOT PROPERLY SECURED TO STRUCTURE. LACKS REQUIRED RAIN CAP. 37- NEW INTERIOR ELECTRICAL SUB-PANEL INSTALLED. NO PERMIT. UNIT B DIRECTLY INTO CITATION: NO N/O/V ISSUED. 1) BEDROOM WINDOWS HAS BEEN ALTERED, DOES NOT ALLOW FOR RAPID EGRESS IN CASE OF FIRE OR PANIC. 2) NORTHEAST BEDROOM WINDOW HAS WROUGHT IRON SECURITY BARS INSTALLED, WILL NOT ALLOW FOR RAPID EGRESS IN CASE OF FIRE OR PANIC. 3) SEWER LINE HAS BEEN REPLACED FROM ORIGINAL, LOCATED ON NORTH SIDE OF STRUCTURE, NOT INSTALLED PROPERLY. NO SECURED PERMITS. 4) WATER LINES HAS BEEN REPLACED FROM ORIGINAL, NO SECURED PERMITS. 5) FRONT DOOR JAMB BROKEN, DOOR WILL NOT SECURE AS INTENDED. 6) LIVINGROOM WINDOW DOES NOT PROPERLY FIT INTO WINDOW FRAME LEAVING OPENINGS TO EXTERIOR ELEMENTS. 7) LIVINGROOM WINDOW BROKEN. 8) KITCHEN ENTRY DOOR LACKS REQUIRED WEATHER STRIPPING. 9) KITCHEN ENTRY DOOR PANELS CRACKED/BROKEN ALLOWS EXTERIOR ELEMENTS TO ENTER INTO LIVING SPACE. 10) INTERIOR ELECTRICAL SUB-PANEL HAZARDOUSLY DOUBLE LUGGED. 11) INTERIOR SUB-PANEL FUSE HOLDER ALTERED TO A POINT OF NO LONGER USABLE. 12) FRONT DEAD PLATE NOT PROPERLY INSTALLED. 13) LIVINGROOM CEILING LIGHT FIXTURE NOT PROPERLY INSTALLED. 14) KITCHEN LIGHT FIXTURE MISSING PROTECTIVE COVER. 15) BATHROOM LIGHT FIXTURE MISSING PROTECTIVE COVER. 16) DWELLING LACKS REQUIRED SMOKE DETECTOR. 17) LIVING ROOM CEILING SHOWS WHERE ROOF LEAKS. 18) PERMANENT SOURCE OF HEAT (HEATER) DOES NOT OPERATE AS INTENDED, OCCUPANT RESORTS TO USING GAS STOVE FOR HEAT. 19) SEWER LINE OPEN AND NOT SEALED AS INTENDED, ALLOWS FOR SEWER GASES TO ESCAPE, AND IF BACKS UP SEWER TO GO DIRECTLY ONTO GROUND. 20) KITCHEN FAUCET LEAKS AT HANDLE. 21) BATHROOM SINK LEAKS AT WASTE WATER LINES. 22) TUB/SHOWER AREA WALL COVERING DETERIORATED, USE OF WRONG MATERIAL FOR REPAIR, PAINT. 23) EXTERIOR WATER HEATER ENCLOSER NOT PROPERLY SECURED TO STRUCTURE. 24) BATHROOM DOOR JAMB AND MOULDING BROKEN. 25) KITCHEN FLOOR MISSING REQUIRED FLOOR COVERING.
05/10/2011 VIOL - ILLEGAL ADDITION DCOX Item closed
05/10/2011 LUC - ILLEGAL DWELLING UNIT DCOX Item closed
05/10/2011 LUC - VIOL OF SITE PLAN - COND DCOX Item closed
05/10/2011 NPO - UNSECURED BUILD OR STRUC DCOX Item closed
05/10/2011 VIOL(BL) - DETACHED STRUCTURES DCOX Item closed
05/10/2011 VIOL(BL) - FOUNDATION DCOX Item closed
05/10/2011 VIOL(BL) - LIVING AREAS DCOX Item closed
05/10/2011 VIOL(BL) - ROOF DCOX Item closed
05/10/2011 NPO(EL)-MAIN/PANEL/SUB/DISCONT DCOX Item closed
05/10/2011 VIOL(EL) - CIRCUITS DCOX Item closed
05/10/2011 VIOL(EL)-SUBPANELS/DISCONNECTS DCOX Item closed
05/10/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX DCOX Item closed
05/10/2011 VIOL(EL) - FIXTURES DCOX Item closed
05/10/2011 NPO(PL)-PLUMBING SYSTEM & FX DCOX Item closed
05/10/2011 NPO(PL)-GAS SUPPLY/CONNECT DCOX Item closed
05/10/2011 NPO(PL)-SEWAGE DISPOSAL (SYS) DCOX Item closed
05/10/2011 VIOL(PL) - FIXTURES DCOX Item closed
05/10/2011 NPO(PL)-WATER HEATERS DCOX Item closed
05/10/2011 NPO(HC)-COOLING DCOX Item closed
05/10/2011 NPO(HC)-NO VENTILATION DCOX Item closed
05/10/2011 NPO(HC)-HEATING & VENTILATION DCOX Item closed
05/10/2011 NPO(DL)-DILAPIDATED STRUCTURE DCOX Item closed
05/10/2011 VIOL(DL)-NUISANCE STRUCTURE(H) DCOX Item closed
05/10/2011 VIOL(SA) - BATHS DCOX Item closed
05/10/2011 VIOL(SA) - KITCHEN DCOX Item closed
05/10/2011 NPO - INSECTS/PESTS DCOX Item closed
05/10/2011 VIOL(PC) - RODENTS DCOX Item closed
05/10/2011 NPO - EGRESS DCOX Item closed
05/10/2011 NPO - SMOKE ALARMS DCOX Item closed
05/10/2011 NPO - REFUSE/TRASH/DEBRIS DCOX Item closed
05/10/2011 NPO - VEGETATION NUISANCE DCOX Item closed
05/10/2011 NPO - WEEDS/GRASSES DCOX Item closed

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T08DV00988
Case Status: REFERRED
Total Completed Case Activity Conditions: 4
Date Name
05/02/2011 CONTACTED BY PHONE
06/16/2008 CONTACTED BY MAILING
03/04/2008 CITATION ISSUED
05/10/2011 VIOLATION CLOSED

Documents

File Name Document Type  
1ST INSP.PDF DOCUMENTS VIEW
INSP NOTE.PDF DOCUMENTS VIEW
NOV_02.13.08.PDF DOCUMENTS VIEW
FAX.PDF DOCUMENTS VIEW
VACATE NOV.PDF DOCUMENTS VIEW
SUPP NOV.PDF DOCUMENTS VIEW
VIOL REPORT.PDF DOCUMENTS VIEW
INSP NOTE 02.06.08.PDF DOCUMENTS VIEW
INSP NOTE.PDF DOCUMENTS VIEW
P+ ZONE SCRN.PDF DOCUMENTS VIEW
P+ BASE SCRN.PDF DOCUMENTS VIEW
NOTE 11.13.07.PDF DOCUMENTS VIEW
ASSR PG.PDF DOCUMENTS VIEW