Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

01/04/2008

Applicant:

BROWN LAURA G

Description:

LOST ELECTRIC IN PART OF HOUSE WHILE OUT OF TOWN THIS PAST WEEKEND, KITCHEN (INCLUDING REFRIGERATOR), ELECTRIC FURNACE, ELECTRIC WATER HEATER, A COUPLE OTHER ROOMS IN HOUSE; DOES HAVE ONE SPACE HEATER; WHEN TRIED TO RESET BREAKER(S), SPARKS AT BREAKER BOX; CALLER RETURNED HOME ON SAT 12/29/07; PROP MGMT HAVE ADVISED CALLER TO USE EXTENSION CORDS TO CONNECT TO PARTS OF HOUSE STILL WITH ELECTRIC

Outstanding Inspections

Case Number: T08DV00227
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
02/01/2008 NPO(EL)-MAIN/PANEL/SUB/DISCONT JHURD Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T08DV00227
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/07/2008 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE, MET WITH OCCUPANT, OCCUPANT EXPLAINED WHAT HAPPENED, WHEN RETURNED FROM NEW MEXICO, ECT TO HOUSE WAS OFF, LOST FOOD, HEATING, STATED CALLED MGMY CO. WAS TOLD TO USE HEATERS W/EXTENSION CHORD TO OUTLET THAT WORKS. OCCUPANTS ALSO STATED CASCADE ELECT WAS OUT OVER WEEKEND, MADE REPAIRS, RESTORED ELECT. OCCUPANT STILL USING SPACE HEATER, ORIGINAL HEATER SHOWS POWER AT THIS TIME. L/R-SHOWS 2 SETS OF CONVENIENCE OUTLETS. ORIGINAL APPROX 18" FROM FLOOR SHOWS CORRECT WIRING, 2ND SET APPROX 24" FROM FLOOR SHOWS OPEN GROUND UNDER TEST. THIS APPEARS THROUGHOUT THE HOUSE, OCCUPANT SHOWED INTERIOR SUB PANEL, LOCATED IN KITCHEN CUPBOARD, SHOWED HAZARDS, ALSO LOOKED AT EXTERIOR MAIN SERVICE PANEL, ALSO SHOWED HAZARDS. BUSS BAR SHOWS STRESS DUE TO OVER HEATING, WARPED, TARNISHED AND PITTED. ALSO NEW WORK HAS BEEN DONE, NEW CONDUCT GOING INTO(WOP) LAUNDRY ROOM. OCCUPANT STATED HER BROTHER DONE WORK, IS AN ELECTRICIAN, (RESEARCH PERMIT) DUE TO HAZARDS TO BUSS BAR NO OTHER SPACES AVAILABLE. INTERIOR SUB PANEL(FUSE) ENCLOSED IN KITCHEN CABINETS, LACKS PROPER CLEARANCE. CONDUCTORS SHOW EVIDENCE OF OVERHEATING AND MELTING OFF EXTERIOR INSULATION. SOME FUSES UNDETERMINED ON AMP STRANDED WIRE CONDUCTOR(MORE WOP) NOT INSTALLED PROPERLY FOR WIRING TERMINATION. APPEARS ADDITION TO SOUTH OF MAIN STRUCTURE, CONVENIENCE OUTLET SHOWS OPEN GROUND. ADDITION TO FRONT NORTH SIDE OPEN GROUND UNDER TEST. B/R ADDED ON TO OPEN GROUND UNDER TEST. NONE OF THESE OUTLETS WOULD PASS INSPECTION(WOP).
02/01/2008 INSP - FOLLOW UP CODE ENFORCE JHURD Approved ELECTRICAL ISSUES ON NOV COMPLIANT. PERMITS UPGRADED AND FINALED. CLOSE CASE COMPLIANT

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T08DV00227
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
01/11/2008 CONTACTED BY PHONE
01/11/2008 NOTICE OF VIOLATION ISSUED
02/07/2008 VIOLATION CLOSED

Documents

File Name Document Type  
NOV 01-14-08.PDF DOCUMENTS VIEW