Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

11/09/2007

Applicant:

CAPIN NEIL O & JOSEFINA TR

Description:

Full inspection done following a complaint called in on a blocked exit. Exit was blocked by tables. Had manager remove same. "B" and "A-2" occupancy. Albert Lopez - managr; 886-9573 / Kim Mars 488-6909 / C of O on premises.

Completed Inspections

Case Status: COMPLETE
Case Number: T07FR02272
Case Description: INSPECTION
Total Completed Inspections - 5
End Date Description Inspector Results Comments
11/09/2007 VIOL - COMPRESSED GASES BCOBB Approved Securing tanks: IFC2006 [TFC with modifications] 3003.5.3 Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1. Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2. Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in seller's warehouses not accessible to the public. Nesting shall be allowed provided the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4. Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. ______ Please secure tanks in an approved manner. Re-inspection date scheduled on or after Nov. 28, 2007. If you have any questions or concerns please call Inspector Cobb at 791-4502 Thank you, _____________________________________________ Brian Cobb, Inspector, Tucson Fire Department __________________________I have received a copy of this inspection report. Building Representative _____________________________________________ Captain
11/09/2007 VIOL - MEANS OF EGRESS BCOBB Approved Blocked Exit: TFC 504.2 Maintenance of exterior doors and openings. Exterior doors and their function shall not be eliminated without prior approval. ______ Keep exit clear and usable.
11/09/2007 VIOL - MEANS OF EGRESS BCOBB Approved Emergency lighting: IFC2006 [TFC with modifications] / 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: [where currently located] ______Fix all inoperative emergency lights.
11/09/2007 INSP - FULL BCOBB Approved Please correct the following Tucson Fire Code [IFC 2006 with modifications] violations:
05/09/2008 INSP - REINSPECTION BCOBB Approved All approved as of 1/14/2008