Case: T07FR02000
Case Details
Entered Date:
10/08/2007
Applicant:
CARSON TERRANCE G & DIANA L JT/RS
Description:
Full Inspection
Completed Inspections
Case Status: COMPLETE
Case Number: T07FR02000
Case Description: INSPECTION
Total Completed Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2007 | INSP - FULL | DRAMIREZ | Approved | TFC 102.3 Shall provide Cof o O |
| 10/08/2007 | VIOL - PRECAUTION AGAINST FIRE | DRAMIREZ | Approved | TFC 304.1.1 Accumulation of weeds dried brush, dried grass creating a fire hazard shall be prohibited. |
| 10/08/2007 | VIOL - COMPRESSED GASES | DRAMIREZ | Approved | TFC 3003.5 Compressed gas cylinders shall be secured against accidental dislodgement. |
| 10/08/2007 | VIOL - FLAMMABLE LIQUIDS | DRAMIREZ | Approved | TFC 3403.5 Containers shall be labled identifying the product. Empty containers shall be labled "EMPTY" or shall be removed. |
| 10/08/2007 | VIOL - BUILDING SVCS & SYSTEMS | DRAMIREZ | Approved | TFC 605.6 Open wire splices shall be prohibited (outside shed). Approved cover plates shall be provided. |
| 10/08/2007 | VIOL - BUILDING SVCS & SYSTEMS | DRAMIREZ | Approved | TFC 605.3 Shall provide a working space of no less then 30 inches in front of any electrical pannel. |
| 10/08/2007 | VIOL - BUILDING SVCS & SYSTEMS | DRAMIREZ | Approved | TFC 605.5 Extension cords shall not be a substitute for permanent wiring. |