Case: T07FR00317
Case Details
Entered Date:
02/13/2007
Applicant:
OFFSHORE INTERNATIONAL INC
Description:
Full Inspection
Outstanding Inspections
Case Number: T07FR00317
Case Status: FIELD
Case Description: INSPECTION
Total Outstanding Inspections - 6
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2007 | INSP - FULL | BCORRALE | Correction Required | On 2-8-07 a fire prevention inspection was conducted at Offshore Group, 8350 E. Old Vail Rd. Please correct the following violations of the Tucson Fire Code. References are from the 2003 International Fire Code, with modifications. |
| 02/14/2007 | VIOL - EMERGENCY PLAN/PREPARE | BCORRALE | Violation | 1. No Material Safety Data Sheets (MSDS) for Janitors' closet. 407.2 Material Safety Data Sheets. Material Safety Data Sheets MSDS) for all hazardous materials shall be readily available on the premises.TFC2003 ***Provide MSDS sheets on premises. |
| 02/14/2007 | VIOL - BUILDING SVCS & SYSTEMS | BCORRALE | Violation | 2. Electrical panel blocked. 605.3 Working spaces. The working space shall not be less than the width of the electrical service equipment. No storage of any materials shall be located within the designated working space.TFC2003 ***Unblock electrical panel. |
| 02/14/2007 | VIOL - BUILDING SVCS & SYSTEMS | BCORRALE | Violation | 3. Extension cord used to power equipment.(secure room). 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. ***Replace extention cord with UL approved power strip. |
| 02/14/2007 | VIOL - FIRE RESIST.RATED CONST | BCORRALE | Violation | 4. Ceiling tiles missing, not seated. -Secure room -outside of breakroom 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings, and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.TFC2003 ***Replace/reseat ceiling tiles. |
| 02/14/2007 | VIOL - HAZARDOUS MATERIALS,GEN | BCORRALE | Violation | 5. Indoor Propane storage neccessitates NFPA 704 placard on outside of building. 2703.5 Hazard identification signs. Unless otherwise exempted by the fire code official, visible hazard identification signs as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. ***Install NFPA 704 placards outside of building where forklifts will be stored overnight. |