Case: T07FR00148
Case Details
Entered Date:
01/18/2007
Applicant:
DHS PROPERTY INVESTMENTS LTD PARTNERSHIP
Description:
Full Fire Inspection
Outstanding Inspections
Case Number: T07FR00148
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
INSP - FULL | None | Not Inspected | ||
01/18/2007 | VIOL - PRECAUTION AGAINST FIRE | NSPRENGE | Violation | 304.1 Waste accumulation prohibited. Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. Make storage of boxes orderly or remove from break area all together. |
01/18/2007 | VIOL - PRECAUTION AGAINST FIRE | NSPRENGE | Violation | 305.1 Clearance from ignition sources. Clearance between ignition sources, such as light fixtures, heaters and flame-producing devices, and combustible materials shall be maintained in an approved manner. Remove combustible materials behind desk and near electrical conduit. |
01/18/2007 | VIOL - BUILDING SVCS & SYSTEMS | NSPRENGE | Violation | 605.4.2 Power supply. Relocatable power taps shall be directly connected to a permanently installed receptacle. Disconnect 'piggybacked' power taps and connect to seperate power supply in a permanently installed receptacle. |
01/18/2007 | VIOL - BUILDING SVCS & SYSTEMS | NSPRENGE | Violation | 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Remove extension cord in break area. |
Completed Inspections
Case Status: COMPLETE
Case Number: T07FR00148
Case Description: INSPECTION
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/30/2007 | COMPL - REINSPECTION | NSPRENGE | Approved |