Case: T07DV11828
Case Details
Entered Date:
10/31/2007
Applicant:
SHAH DILIP L & INDU D TR
Description:
IMPROPERLY GROUNDED ELECTRICAL RUNNING FROM PANEL ON REAR/OPPOSITE END OF MAIN OFFICE
Outstanding Inspections
Case Number: T07DV11828
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/18/2008 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Violation | ELECTRICAL MODIFICATIONS HAVE DONE TO THE SERVICE EQUIPMENT WITH OUT PERMITS. 1. TWO NEW PANEL BOARDS AND (5) RACEWAYS WERE ADDED TO THE SERVICE EQUIPMENT SUPPLYING POWER TO UNKNOWN AREAS. 2. SERVICE EQUIPMENT IS NOT LABELED THE TWO NEW PANEL BOARDS MAIN SHUT OFF LOCATION IS UNKNOWN. 3. WESTSIDE NEW PANEL BOARD HAS ½ INCH CONDUIT WITH NON WEATHER PROOF CONNECTORS IN THE RACEWAY, LOOSELY FASTENED TO THE GUTTER BOX. 4. NEW ¾ CONDUIT FROM UPPER GUTTER BOX TO UNKNOWN LOCATION ABOVE THE ROOF 5. WESTSIDE PANEL BOARD HAS 1 ½ CONDUIT PVC RACEWAY TO AN LB TO GUTTER BOX. THE LB IS INSTALLED IMPROPER NO ACCESS. 6. WESTSIDE PANEL BOARD HAS NO SCHEDULE INSIDE. MISSING COVER PLATES IN THE PANEL. 7. WESTSIDE PANEL BOARD GROUND NOT PROPERLY INSTALLED (STRANDS HAVE BEEN SEPARATED TO ENTER DIFFERENT TERMINALS.) MAIN DISCONNECT# 1 1. A PHASE HAS MISSING INSULATOR. A CLAMP WAS INSTALLED TO THE KNIFE BLADE RECEPTOR 2. THE SERVICE PANEL AND EQUIPMENT HAS DETACHED FROM THE WALL 3. RISER NOT PROPERLY STRAPPED DISCONNECT NUMBER 2 1. UNMARKED NEUTRAL 2. OPEN KNOCK OUTS TO SUB PANEL EAST OF #2 MAIN 3. SUB PANEL EAST OF #2 MAIN NOT RAIN TIGHT CONSTRUCTION DISCONNECT NUMBER 3 1. FUSE BOX HAS BEEN GUTTED OUT AND CONVERTED TO AN UNAPPROVED JUNCTION BOX 2. OPEN KNOCK OUTS 3. BUSHINGS MISSING IN CONDUIT NIPPLES EASTSIDE PANEL BOARD 1. MAIN SHUT OFF TO PANEL BOARD LOCATION UNKNOWN 2. ADDED CIRCUITS BELOW PANEL BOARD HAS E.M.T CONNECTORS OF NON RAIN TIGHT TYPE 3. NON G.F.C.I. RECEPTACLE INSTALL UNDER PANEL BOARD 4. ROMEX HAS BEEN INSTALLED UNPROTECTED EXTERIOR OF THE PANEL BOARD GUTTER BOXES 1. GUTTER BOXES NOT RAIN PROOF BACKER BOARD 1. WOOD BACKER BOARD IS NOT WEATHER PROTECTED AND IS DETERIORATED AND NOT PROPERLY FASTENED TO THE STRUCTURE. METER BOX 1. NIPPLE HAS BEEN DISLODGED DUE TO THE SHIFTING OF THE METER BASE ENCLOSURE FROM THE WALL |
04/11/2008 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | JVALDEZ | Item closed | |
04/11/2008 | VIOL(EL) - CIRCUITS | JVALDEZ | Item closed | |
04/11/2008 | VIOL(EL)-SUBPANELS/DISCONNECTS | JVALDEZ | Item closed | |
04/11/2008 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JVALDEZ | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T07DV11828
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/11/2008 | INSP - FOLLOW UP CODE ENFORCE | JVALDEZ | Approved | NEW SERVICE UPGRAD COMPLETED UNDER PERMIT |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T07DV11828
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
03/04/2008 | CONTACTED BY PHONE |
01/24/2008 | CONTACTED BY MAILING |
04/15/2008 | VIOLATION CLOSED |