Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

10/31/2007

Applicant:

SHAH DILIP L & INDU D TR

Description:

IMPROPERLY GROUNDED ELECTRICAL RUNNING FROM PANEL ON REAR/OPPOSITE END OF MAIN OFFICE

Outstanding Inspections

Case Number: T07DV11828
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
01/18/2008 INSP - INITIAL CODE ENFORCMENT JVALDEZ Violation ELECTRICAL MODIFICATIONS HAVE DONE TO THE SERVICE EQUIPMENT WITH OUT PERMITS. 1. TWO NEW PANEL BOARDS AND (5) RACEWAYS WERE ADDED TO THE SERVICE EQUIPMENT SUPPLYING POWER TO UNKNOWN AREAS. 2. SERVICE EQUIPMENT IS NOT LABELED THE TWO NEW PANEL BOARDS MAIN SHUT OFF LOCATION IS UNKNOWN. 3. WESTSIDE NEW PANEL BOARD HAS ½ INCH CONDUIT WITH NON WEATHER PROOF CONNECTORS IN THE RACEWAY, LOOSELY FASTENED TO THE GUTTER BOX. 4. NEW ¾ CONDUIT FROM UPPER GUTTER BOX TO UNKNOWN LOCATION ABOVE THE ROOF 5. WESTSIDE PANEL BOARD HAS 1 ½ CONDUIT PVC RACEWAY TO AN LB TO GUTTER BOX. THE LB IS INSTALLED IMPROPER NO ACCESS. 6. WESTSIDE PANEL BOARD HAS NO SCHEDULE INSIDE. MISSING COVER PLATES IN THE PANEL. 7. WESTSIDE PANEL BOARD GROUND NOT PROPERLY INSTALLED (STRANDS HAVE BEEN SEPARATED TO ENTER DIFFERENT TERMINALS.) MAIN DISCONNECT# 1 1. A PHASE HAS MISSING INSULATOR. A CLAMP WAS INSTALLED TO THE KNIFE BLADE RECEPTOR 2. THE SERVICE PANEL AND EQUIPMENT HAS DETACHED FROM THE WALL 3. RISER NOT PROPERLY STRAPPED DISCONNECT NUMBER 2 1. UNMARKED NEUTRAL 2. OPEN KNOCK OUTS TO SUB PANEL EAST OF #2 MAIN 3. SUB PANEL EAST OF #2 MAIN NOT RAIN TIGHT CONSTRUCTION DISCONNECT NUMBER 3 1. FUSE BOX HAS BEEN GUTTED OUT AND CONVERTED TO AN UNAPPROVED JUNCTION BOX 2. OPEN KNOCK OUTS 3. BUSHINGS MISSING IN CONDUIT NIPPLES EASTSIDE PANEL BOARD 1. MAIN SHUT OFF TO PANEL BOARD LOCATION UNKNOWN 2. ADDED CIRCUITS BELOW PANEL BOARD HAS E.M.T CONNECTORS OF NON RAIN TIGHT TYPE 3. NON G.F.C.I. RECEPTACLE INSTALL UNDER PANEL BOARD 4. ROMEX HAS BEEN INSTALLED UNPROTECTED EXTERIOR OF THE PANEL BOARD GUTTER BOXES 1. GUTTER BOXES NOT RAIN PROOF BACKER BOARD 1. WOOD BACKER BOARD IS NOT WEATHER PROTECTED AND IS DETERIORATED AND NOT PROPERLY FASTENED TO THE STRUCTURE. METER BOX 1. NIPPLE HAS BEEN DISLODGED DUE TO THE SHIFTING OF THE METER BASE ENCLOSURE FROM THE WALL
04/11/2008 NPO(EL)-MAIN/PANEL/SUB/DISCONT JVALDEZ Item closed
04/11/2008 VIOL(EL) - CIRCUITS JVALDEZ Item closed
04/11/2008 VIOL(EL)-SUBPANELS/DISCONNECTS JVALDEZ Item closed
04/11/2008 NPO(EL)-WIRING/SWITCH/OUTLT/FX JVALDEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T07DV11828
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
04/11/2008 INSP - FOLLOW UP CODE ENFORCE JVALDEZ Approved NEW SERVICE UPGRAD COMPLETED UNDER PERMIT

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T07DV11828
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
03/04/2008 CONTACTED BY PHONE
01/24/2008 CONTACTED BY MAILING
04/15/2008 VIOLATION CLOSED