Case: T07DV11390
Case Details
Entered Date:
10/22/2007
Applicant:
DI PIERO INVESTMENTS LLC
Description:
THE INSIDE OF #61 IS BEING REMODELED. ONE HOUSE IS SPLIT IN HALF. HALF IS RENTED OUT AND THE OTHER HALF IS THE OFFICE. CALLER STATES THIS HAS BEEN DONE WOP. REFRAMED THE FURNACE ROOM ON THE OUTSIDE OF THE HOUSE. PAINTED IT TO MATCH THE HOUSE AND INSTALLED A NEW FURNACE. REMODELING THE POOL HOUSE THAT IS INSIDE THE POOL AREA. PREVIOUS CASE WAS CLOSED NO VERIFY. SEE T07DV10756.
Outstanding Inspections
Case Number: T07DV11390
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 6
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
| VIOL(EL) - CIRCUITS | None | Not Inspected | ||
| VIOL(EL)-SUBPANELS/DISCONNECTS | None | Not Inspected | ||
| NPO(PL)-PLUMBING SYSTEM & FX | None | Not Inspected | ||
| NPO(PL)-WATER HEATERS | None | Not Inspected | ||
| 10/24/2007 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Violation | ADDED ELECTRICAL RUN ON NORTH WALL FROM SERVICE PANEL TO NORTHWEST CORNER OF STRUCTURE. ADDED SUBPANEL NEAR SERVICE PANEL. MAIN SERVICE PANEL DOOR IS DAMAGED AND DOES OPERATE PROPERLY. ADDED DRAIN PIPE AND VENT AT THE NORTHEAST PORTION OF THE STRUCTURE WITHOUT PERMITS. WATER HEATER VENT PIPE IS TOO LOW. WATER HEATER LACKS PRESSURE RELIEF PIPE. WATER CLOSET IS BEING USED AS STORAGE. PHOTOS TAKEN. RM |
Completed Inspections
Case Status: COMPLIAN
Case Number: T07DV11390
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2007 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | FOUND ELECTRICAL RUN IS FOR PARK LIGHT AND HAS PERMITS. SMALL SUBPANEL IS A DIRECT REPLACEMENT PLUG FOR ORIGINAL 220 FOR DRYER AS WELL AS VENT PIPE AND DRAIN FOR WASHER. WATER HEATER NOW HAS PROPER VENT PIPE AND DRAIN PIPE. ALL ITEMS REMOVED FROM WATER CLOSET. RM |
Completed Activity Special Conditions
Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T07DV11390
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 10/23/2007 | CONTACTED BY PHONE |
| 10/25/2007 | NOTICE OF VIOLATION ISSUED |