Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

07/30/2007

Applicant:

ALVERNON PLACE LLC

Description:

ALARM 45087: ROOF COLLAPSE

Outstanding Inspections

Case Number: T07DV07052
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
07/28/2007 VIOL(EL) - CIRCUITS MROMERO Violation
07/28/2007 VIOL(DL)-NUISANCE STRUCTURE(H) MROMERO Violation
12/28/2007 NPO(DL)-DILAPIDATED STRUCTURE MROMERO Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T07DV07052
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/28/2007 INSP - INITIAL CODE ENFORCMENT MROMERO Approved SITE VISIT: ROOF COLLAPSE, CALLOUT. 2:00 PM - 6:30 PM AFTER HOURS OFFICE COMPLEX WEST SIDE OF ALVERNON NORTH OF 6TH ST. TFD ON SITE 2ND STORY ROOF WALK COMPLETE COLLAPSE SOUTHEND SLUICE, METAL LATH, WOOD FALLEN ONTO STAIRWELL EXPOSING ELECTRICAL CONDUIT, AND PULLING THEM DOWN. TFD CUT ALL POWER TO ENTIRE COMPLEX MULTIPLE SUITES AFFECTED CONDEMNATION OF COMPLEX. NOV ISSUED AND SIGNED BY ANNA WILLIAMS, JOINT OWNER DEMO CONTRACTOR ON SITE WHILE INSPECTOR PRESENT. DEMO COMPANY CHANGING OUT LOCKS TO KEEP PEOPLE FROM ENTERING MANY PEOPLE COMING IN AT ALL FOUR GATES TO VIEW AFTER SEE IT ON THE NEWS. PEOPLE ARE WALKING IN UNDER CAUTION TAPE WITH CHILDREN. PROPERTY POSTED UNFIT TO OCCUPY. INSPECTOR D COX ON SITE AND AGREES WITH NOV GIVEN, ASSESSMENT AND CONDEMNATION. TFD STATES THEY DO NOT FEEL IT WAS WEATHER RELATED. THEY ARE NOT SURE OF WHAT MADE THE LID COLLAPSE. NO SIGNS OF WATER RETAINING INSIDE OF LID. POSSIBLE SIGNS OF SOME TYPE OF STRUCTURAL FAILURE, LID COLLAPSE, NOT ROOF? LID COLLAPSED ONTO SECOND STORY DECK RAFTERS, METAL LATH, 2X4 HANGING ONTO COURTYARD IN BREEZEWAY SOME MATERIAL INTO OFFICES. DUE TO AMOUNT OF DEBRIS, INSPECTOR NOT ABLE TO HAVE ACCESS INTO OFFICE. MOST OFFICES HAVE CHANGED LOCK, OWNER DOES NOT HAVE KEYS. ANOTHER CONDTION: LIGHTNING AND HEAVY RAIN WHILE ON SITE. WEATHER CONDITION AFFECTING DEBRIS BLOCKING ENTRANCES, INSPECTION INSPECTION OF ROOF, VIEW NO WATER PUDDLING, ALL DRAINS CLEAR OF DEBRIS, LIGHTNING THROUGHOUT, NOT ABLE TO STAY ON ROOF MORE THAN 1 MINUTE. ADVERSE WEATHER CONDITIONS. DAMAGE REPORT- BUILDING: LID ON SOUTH END OF COMPLEX HAS COLLAPSED ON TOP OF STAIRWELL AND DECK. NO ACCESS TO VIEW DAMAGE IN INTERIOR OF SUITES. ELECTRICAL: ALL ELECTRICITY HAS BEEN CUT BY TFD AT PANELS, MULTIPLE EXPOSED AND HANGING CIRCUITS, TO INCLUD BROKEN AND PULLED OUT J-BOXS. PLUMBING: N/A MECHANICAL: N/A REMARKS: COMPLEX HAS BEEN CONDEMNED. NORTHEND TENANT ARE ALLOWED TO REMOVE ITEMS UNTIL WORK/REPAIRS ARE COMPLETED. SOUTHEND NOT ABLE TO RETRIEVE UNTIL DEMO AND REMODEL COMPLETED. INSPECTOR: M ROMERO NOTICE AND ORDER- 0 DAYS TO SECYRE STRUCTURE(S) FROM UNAUTHORIZED ENTRY. INDEMNIFICATION- IN EXCHANGE FOR BEING ALLOWED BY THE CITY TO CONTROL ACCESS TO THE PREMISES RATHER THAN HAVE THE CITY FENCE OR OTHERWISE SECYRE THE PREMISES, THE UNDERSIGNED AGREES TO INDEMNIFY, DEFEND AND HOLD HARMLESS THE CITY FROM ANY LIABILITY OR CLAIM FOR DAMAGES ARISING OUT OF INJURY, TO THE UNDERSIGNED OR ANY THIRD PERSON OR THEIR PROPERTY, SUSTAINED ON OR ADJACENT TO THE PREMISES. SIGNED 7/28/07 (COPIES STORED ON SIRE.) NOTICE OF VIOLATION: TC 16-14 (C) 3,5,11 DILAPIDATED STRUCUTRES CONSTITUTING A NUISANCE- LID ON UPPER LEVEL HAS COLLAPSED, BRINGING DOWN ELECTRICAL CONDUIT, WOOD, STUCCO, METAL AND LATH TC 16-11 (C)1 ELECTRICAL SYSTEM- COLLAPSE HAS DAMAGED MULTIPLE SUITES. POWER CUT AT BREAKERS BY TUCSON FIRE. ACTIONS NECCESARY TO CORRECT- HIRE A LICENSED CONTRACTOR TO REMOVE ALL DEBRIS. HIRE A LICENSED ELECTRICAL CONTRACTOR TO REMOVE AND REPLACE DAMAGED CIRCUITS AND EVALUATE TO ENSURE DAMAGED CIRCUITS ARE NOT ENERGIZED. STRUCUTRAL ENGINEER SHOULD BE BROUGHT IN TO ENSURE BUILDING IS SAFE PRIOR TO PERSONS GAINING ACCESS. ALL REMODELING WILL BE DONE UNDER PERMITS SECURED AT DSD 201 N STONE. 30 DAYS ALLOWED TO SECURE PERMITS, 45 DAYS TO COMPLETE WORK. (SIGNED 7/28/07, COPY STORED ON SIRE)
12/28/2007 INSP - FOLLOW UP CODE ENFORCE MROMERO Approved FOLLOW UP INSPECTION VIEW IN SIRE SHOWS PERMITS HAVE BEEN SECURED FOR TOOF AND SOFFIT REPAIR T07CM04657 ISSUED 12-12-07. I INFORMED TERESA AND LUCY FOLLOW UP 180 DAYS. MR.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T07DV07052
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
08/03/2007 CONTACTED BY PHONE
08/03/2007 CONTACTED BY MAILING
09/22/2008 NOTICE OF VIOLATION ISSUED
09/16/2008 VIOLATION CLOSED
08/15/2008 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
DAMAGE REPORT.PDF DOCUMENTS VIEW
NOTICE OF VIOLATION.PDF DOCUMENTS VIEW
NOTICE&ORDER.PDF DOCUMENTS VIEW
STRUCTURAL EVALUATION.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW
None IMAGES VIEW