Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

07/25/2007

Applicant:

CURIEL JOHN R & MARYLIN JT/RS

Description:

RAIN COMING IN UNDER THE BACK DOOR. SHE SAYS HER LANDLORD HAS ADDED AN AZ ROOM TO BACK OF HOUSE WOP. W & D ADDED AND THE DRYER IS VENTED STRAIGHT TO THE OUTSIDE. ONE ROOM THAT WAS ADDED HAS NO WINDOW. LANDLORD WON'T RETURN CALLS AS FAR AS THE WATER COMING IN. CALL CALLER BEFORE GOING OUT SO SHE IS THERE.

Outstanding Inspections

Case Number: T07DV06891
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 9
End Date Description Inspector Results Comments
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - ROOF None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
NPO - EGRESS None Not Inspected
NPO - SMOKE ALARMS None Not Inspected
07/31/2007 INSP - INITIAL CODE ENFORCMENT RMENDOZA Violation LARGE SKYLIGHT ADDED IN THE KITCHEN CEILING/ROOF. REAR CENTER BEDROOM WINDOW REMOVED AND NOW ONLY ALLOWS ONE FORM OF EGRESS. WASHER/DRYER ADDED AT SOUTHEAST CORNER OF STRUCTURE. PORCH ATTACHED TO STRUCTURE ON SOUTHSIDE OF PROPERTY. APPROX 10'X 30'. UNIT LACKS SMOKE DETECTORS MAIN SERVICE PANEL HAS MISMATCHED BREAKERS. PANEL SHOWS DOUBLE LUGGING, LACKS IMPROPER LABELING. ADDED CIRCUIT TO GARAGE IS NOT PROPERLY ATTACHED. ADDED CIRCUIT ENTERING REAR DOOR. OUTLETS IN ECLOSED PORCH SOUTH WALL ARE INOPERABLE. ADDED ELECTRICAL OUTLETS TO INCLUDE A 220 OUTLET ADDED IN WASHER/DRYER AREA. ½ BATH OUTLET IS NOT GFCI PROTECTED AND SHOWS OPEN GROUND. HALLWAY OUTLET SHOWS OPEN GROUND. SOUTHSIDE CENTER BEDROOM OUTLET SHOWS OPEN GROUND. KITCHEN LACKS GFCI PROTECTION. DINING ROOM OUTLET NORTHEAST CORNER SHOWS OPEN GROUND. OUTLET NEAR FRONT DOOR IS INOPERABLE. LIVING ROOM SOUTHWEST OUTLET SHOWS OPEN GROUND. MAIN BATHROOM OUTLET HAS BEEN MODIFIED WITH A PERMANENT MULTI 2-PRONG OUTLET. ELECTRIC WATER HEATER INSTALLED WITHOUT PERMIT BEDROOM ON THE SOUTHEAST CORNER CEILING SHOWS SIGNS OF LEAKS. MATERIAL IS PEELING AWAY FROM SHEETROCK. CENTER BEDROOM CEILING IS BADLY SAGGING AND APPEARS MOIST. OCCUPANTS ARE NOT PROTECTED FROM DAMPNESS OR MOISTURE. ROOF SHOWS SIGNS OF LEAKING. ATTIC INSPECTION SHOWS MOISTURE DUE TO LEAKAGE. INSULATION IS WET. PROPERTY IS NOT REGISTERED AS RENTAL PROPERTY. PHOTOS TAKEN. RM
08/08/2008 VIOL(BL) - ATTACHED STRUCTURES RMENDOZA Item closed
08/08/2008 NPO(EL)-MAIN/PANEL/SUB/DISCONT RMENDOZA Item closed
08/08/2008 NPO(EL)-WIRING/SWITCH/OUTLT/FX RMENDOZA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T07DV06891
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
11/02/2007 INSP - FOLLOW UP CODE ENFORCE RMENDOZA Approved ELECTRICAL PERMIT T07EL01871 ISSUED 10/18/07. RM

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T07DV06891
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
07/27/2007 CONTACTED BY PHONE
10/11/2007 CONTACTED BY MAILING
08/13/2007 NOTICE OF VIOLATION ISSUED
08/12/2008 VIOLATION CLOSED

Documents

File Name Document Type  
4516E8TH.DOC DOCUMENTS VIEW
DSCN2498.JPG IMAGES VIEW
DSCN2500.JPG IMAGES VIEW
DSCN2501.JPG IMAGES VIEW
DSCN2502.JPG IMAGES VIEW
DSCN2503.JPG IMAGES VIEW
DSCN2504.JPG IMAGES VIEW
DSCN2505.JPG IMAGES VIEW
DSCN2508.JPG IMAGES VIEW
DSCN2509.JPG IMAGES VIEW
DSCN2510.JPG IMAGES VIEW
DSCN2513.JPG IMAGES VIEW