Case: T07DV06227
Case Details
Entered Date:
07/06/2007
Applicant:
SOUTH CENTRAL INDUSTRIAL PROPERTIES IX LP
Description:
TFD CALLOUT: ALARM 07-40167
Completed Inspections
Case Status: COMPLIAN
Case Number: T07DV06227
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/06/2007 | INSP - INITIAL CODE ENFORCMENT | RVIDAL | Approved | WENT TO SITE PER SUPERVISOR, RICK SALDATE, ARRIVED AND FOUND A DETACHED STRUCTURE USED FOR WASHING EQUIPMENT BURNED. A COMPRESSOR CAUGHT FIRE AND BURNED AND BURNING STEEL FRAME STRUCTURE WITH FIBERGLASS COVERING. FIBERGLASS COVERING IS TOTAL LOSS AND APPEARS THAT STEEL FRAME OK. WILL NEED TO CHECK FRAME INCLUDING BOLTS FOR HEAT DAMAGE. ELECTRICAL PANEL HAS BEEN TURNED OFF AT BREAKER IN SIDE MAIN SHOP AREA. DISCONNECT AT BURNED AREA HAS BEEN LOCKED OUT WITH CITY LOCK. PROPANE TANK WAS DISCONNECTED AND VALVE TURNED OFF AND CAP WAS LOCKED BY CITY LOCK. WORKER KEPT COPPER TUBING AND REGULATOR THAT WAS REMOVED. FIRE COMPLETED THEIR INVESTIGATION AND RELEASE TO DNR RON RAVAGO FROM TRANSPORTATION WAS ONSITE ADDRESSING WATER WITH OIL AND DIESEL SPILLED FROM COMPRESSOR. AREA WAS SECURED BY MAIN FENCE AND LOCKED AT ALL TIMES BY EMPLOYEES AND OPENED TO GAIN ENTRY ONLY WHEN NEEDED. A PUMPER WAS BROUGHT TO SITE TO RETRIEVE WATER THAT WAS STANDING IN PUDDLES. RON WAS TO REMAIN ON SITE UNTIL WATER ISSUES ADDRESSED. FOUND PALLETS STORED ON DRAINAGE AND WILL BE REMOVED BY MONDAY PER RON. - Mel |
| 11/30/2007 | INSP - FOLLOW UP CODE ENFORCE | RVIDAL | Approved | ALL WORK HAS BEEN COMPLETED. HER PERMIT T07CM03467 AND FINALED ON 11-6-7. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T07DV06227
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 07/16/2007 | CONTACTED BY PHONE |
| 07/16/2007 | NOTICE OF VIOLATION ISSUED |
| 12/12/2007 | VIOLATION CLOSED |
| 07/16/2007 | DAMAGE REPORT |