Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

06/05/2007

Applicant:

ZEPEDA PAUL D JR & DARRELL

Description:

FOUND IN REAR OF HOUSE, SWAMP COOLER RUSTED AND NOT FUNCTIONING PROPERLY HAS BEEN IN A NON-OPERABLE/RUSTED CONDTION FOR FOUR YEARS, HAS BEEN REPAIRED SEVERAL TIMES BY MAINTENANCE, BUT NOT BEEN SUCCESSFUL IN MAKING IT FUNCTION. PADS NOT GETTING SUFFICIENTLY WET. FAN IS WORKING BUT NOT GETTING IN ENOUGH MOISTURE TO COOL APARTMENT. CLAIMS MANAGEMENT TOLD OCCUPANT THAT WHAT WAS DONE IS ENOUGH AND MAY WISH TO LEAVE IF NOT SATISFIED.

Completed Inspections

Case Status: COMPLIAN
Case Number: T07DV05089
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/06/2007 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved MET WITH TENANT, MONICA BENNETT, AND BOYFRIEND, PAUL, WHO MENTIONED THAT BOTTOM LINE WAS COOLER IS OLD, ON ITS LAST LEG, AND DOES NOT ALWAYS PUSH COLD AIR. PAUL MENTIONED THAT LAST YEAR HE FIXED THE COOLER FOR MR.ZEPEDA(SR) AND HE TOLD HIM AT THE TIME THE COOLER WOULD NOT LAST ANOTHER YEAR. MR. ZEPEDA WAS VERY GRACIOUS AND THANKFUL, HOWEVER, SON NOW OWNS THE PROPERTY. TENANT FEELS NEW OWNER(SON) WILL RETALIATE CHECKED THE COOLER, MY FINDINGS ARE AS FOLLOWS: 1.EXTERIOR OF COOLER VERY RUSTED, ALOT OF LIME BUILDUP 2.INTERIOR THE SAME, MOUNTING BRACKET FOR SQUIRREL CAGE RUSTED AWAY IN WEST SIDE. 3.PULL FROM MOTOR TO SQUIRREL CAGE HAS A SEVERE WOBBLE. 4.WATER ONLY GETTING TO PARTS OF COOLER PADS(DUE TO RUST) 5.IMPROPER ELECTRICAL CONNECTION TO COOLER(INSIDE) 6.IMPROPER CONNECTION TO POWER SOURCE, NO WEATHER PROOF BOX. NOV WILL BE ISSUED TO OWNER, PICTURES WERE TAKEN.PN
08/16/2007 INSP - FOLLOW UP CODE ENFORCE GGOODMAN Approved VISITED SITE, FOUND THAT OLD COOLER HAD BEEN REMOVED FROM THE ROOF AND A NEW COOLER HAD BEEN INSTALLED. NEW AZ BOX HAD BEEN INSTALLED UNDER THE ROOF EVE. CHECKED ALL CONNECTIONS ON THE INTERIOR OF COOLER AND FOUND ALL TO BE DONE CORRECTLY ABATING ALL MY ISSUES. - TEMP1

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T07DV05089
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
06/19/2007 NOTICE OF VIOLATION ISSUED
09/10/2007 VIOLATION CLOSED

Documents

File Name Document Type  
NOV 06-20-07.PDF DOCUMENTS VIEW