Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE
Address:

Entered Date:

05/30/2007

Applicant:

GETTEL CHAD A

Description:

TFD CALLOUT 3A

Completed Inspections

Case Status: COMPLIAN
Case Number: T07DV04871
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 6
End Date Description Inspector Results Comments
05/29/2007 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved VISITED SITE, MET WITH TFD CAPTAIN TINNIN WHO MENTIONED SMALL FIRE STARTED OUTSIDE THE STRUCTURE NEAR THE GARBAGE AREA. OUTSIDE SIDING AND RAFTER OVERHANG AND BARGE RAFTERS WERE BURNED. ELECTRICAL SERVICE FROM THE MAIN SERVICE PANEL AT FRONT STRUCTURE WAS ALSO BURNED, WIRING ONLY. BREAKERS WERE TURNED OFF AT THE MAIN SERVICE PANEL. SWGAS SERGIO CHIQUETTE TURNED GAS OFF AT THE METER LEAVING UNIT WITH NO GAS OR ELECTRIC I INFORMED TENANT DAVID SCHMIDT THAT HE WOULD NOT BE ALLOWED TO OCCUPY UNIT WITH NO UTILITIES. DAVID MENTIONED HE HAD COUSINS LIVING ACROSS THE STREET ON THE N/E CORNER OF GLENN AND LOS ALTOS WHERE HE WOULD BE STAYING. HE WAS INFORMED UNIT COULD ONLY BE OCCUPIED DURING THE DAYLIGHT HOURS. COUSINGS CAME AND HELPED MOVE PERSONAL BELONGINGS TRIED CALLING 3 DIFFERENT NUMBERS FOR PROPERTY MANAGEMENT, RECEIVED VOICEMAIL AND LEFT INFORMATION CONCERNING THE FIRE DETAILS AND MY INVOLVEMENT MINIMUM 30 AMP FEEDER REQUIRED/ UNIT IS A RESIDENCE NO GROUNDING SYSTEM AT REAR HOUSE PROPER IDENTIFICATION FOR CIRCUITRY REPLACE BURNED WIRES 1 BREAKER WRONG TYPE DRYER NEEDS TO BE MAX 20 AMP (IT IS NOW 50 AMP) ILLEGAL SPLICE AT CONDUIT TO REAR OF FRONT HOUSE ARTICLE 225 REQUIRES MAIN BREAKER. MET WITH OWNERS/RESPONSIBLE PARTIES OF THE GLENN PROPERTY(KILLI) OF EXG AT THEIR OFFICE, EXPLAINED THE PROBLEMS CONCERNING THE FIRE, THE TWO MAJOR PROBLEMS BEING THE ELECTRICAL AND WORK WITHOUT PERMITS EXPLAINED WHAT JERRY ORTA AND I FOUND OF THE ELECTRICAL PANEL AND HOW THAT LED TO THE RECORDS SERVICE AND WORK WITHOUT PERMITS. KELLI SIGNED TWO COPIES OF NOV AND 1 COPY WAS GIVEN TO KELLI ALONG WITH THE EMERGENCY CALLOUT INFO AND THE DAMAGE REPORT. WENT OVER REPORT AND NOV WITH HER.
05/30/2007 NPO(PL)-GAS SUPPLY/CONNECT GGOODMAN Approved
05/30/2007 VIOL(BL) - ROOF GGOODMAN Approved
05/30/2007 NPO(EL)-MAIN/PANEL/SUB/DISCONT GGOODMAN Approved
05/30/2007 VIOL - ILLEGAL ADDITION GGOODMAN Approved
10/02/2007 INSP - FOLLOW UP CODE ENFORCE GGOODMAN Approved CALLED AND SPOKE TO CURT GETTEL OWNER, WHO MENTIONED THEY HAVE NOT BEEN ABLE TO GET A VARIANCE FROM TWO OF THE NEIGHBORS TO ALLOW THEM TO KEEP THE BUILDING, HOWEVER MR GETTEL'S INSURANCE TOLD THEM THAT THE BUILDING AT ONE TIME WAS ON THE SITE OR PLOT PLAN BUT THAT DSD HAS NO RECORDS AND THAT THIS HAS BECOME A BACK & FORTH BATTLE BETWEEN HIM & DSD AND ALSO INVOLVING THE INSURANCE COMPANY, BUT THAT THEY HAVE TRIED MOVING FORWARD. EXPLAINED TO CURT THAT WE COULD GIVE HIM ADDITIONAL TIME BECAUSE OF DEALING WITH DSD AND INSURANCE BUT AT THE END OF 60 DAYS IF THIS WAS NOT BUTTONED UP IT WOULD GO INTO THE COURT ARENA.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T07DV04871
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
08/18/2007 CONTACTED BY PHONE
02/07/2008 VIOLATION CLOSED

Documents

File Name Document Type  
DAMAGE REPORT.PDF DOCUMENTS VIEW
NOV.PDF DOCUMENTS VIEW