Case: T07DV04184
Case Details
Entered Date:
05/08/2007
Applicant:
HOGAN JAMES W & CONNI S TR
Description:
TENANT IS ELDERLY/// SEWAGE IS BACKING UP INTO THE UNIT/ KITCHEN/TUB/TOILET/ TOLD LANDLORD LAST WEEK AND LANDLORD SAID HE WAS NOT GOING TO FIX IT. TENANT HAS RECORDING OF HIS STATEMENT TO NOT FIX. TENANT HAD A FRIEND COME OUT TO FIX THE PROBLEM BUT FRIEND SAID THEY COULD NOT GO ANY FURTHER WITHOUT THE LANDLORDS OKAY WHICH HE IS NOT PROVIDING. **SHE CALLED AGAIN***05-15-07**HAS FECAL MATTER FLOATING IN WATER IN THE BATHROOM. CALL CALLER (SUSAN) WHEN INSPECTION TO BE DONE.
Outstanding Inspections
Case Number: T07DV04184
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/09/2007 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Violation | BATHROOM AND HALLWAY FLOODED FROM DRAIN BACK UP. SEWER BACKED UP IN THE BATHTUB. OWNER CONTACTED IMMEDIATELY. PLUMBER ARRIVED AND REPAIRED BACKUP. FOUND SOME TIME OF WIPES IN THE PIPES CAUSING BACK UP. REPAIR COMPLETED BEFORE LEAVING THE PROPERTY. FURNACE VENT PIPE IS NOT CONNECTED PROPERLY AND LACKS PROPER CLEARANCE NEAR COMBUSTIBLES. MAIN SERVICE PANELS AT THE REAR OF THE UNITS HAVE ADDED ELECTRICAL CIRCUITS AND SUBPANEL. SERVICE PANELS LACK PROPER ADDRESSING AND LABELING. REAR WALL OUTDOOR OUTLET LACK GFCI PROTECTION. MAIN BATHROOM OUTLET IS INOPERABLE AND LACKS GFCI PROTECTION. KITCHEN LACKS GFCI PROTECTION. SOUTH EAST BEDROOM OUTLETS ARE LOOSE NOT ALLOWING EQUIPMENT TO BE SECURELY INSTALLED. EXPOSED WIRING IN THE FURNACE CLOSET. WASHING MACHING LACKS PROPER DRAIN PIPE. FACIA BOARD ON THE SOUTH WEST CORNER OF THE STRUCTURE HAS DETERIORATED AND LACKS PROPER PROTECTIVE TREATMENT. PHOTOS TAKEN. RM |
Completed Inspections
Case Status: COMPLIAN
Case Number: T07DV04184
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 8
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2007 | NPO(DL)-DILAPIDATED STRUCTURE | RMENDOZA | Approved | |
| 09/28/2007 | NPO(HC)-HEATING & VENTILATION | RMENDOZA | Approved | |
| 09/28/2007 | VIOL(PL) - FIXTURES | RMENDOZA | Approved | |
| 09/28/2007 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Approved | |
| 09/28/2007 | VIOL(EL)-SUBPANELS/DISCONNECTS | RMENDOZA | Approved | |
| 09/28/2007 | VIOL(EL) - CIRCUITS | RMENDOZA | Approved | |
| 09/28/2007 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | RMENDOZA | Approved | |
| 09/28/2007 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | ALL ABATED. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T07DV04184
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 05/17/2007 | CONTACTED BY PHONE |
| 05/14/2007 | CONTACTED BY MAILING |