Case: T07DV04165
Case Details
Entered Date:
05/07/2007
Applicant:
MARTINEZ FRANK C
Description:
DILAPIDATED STRUCTURE 7-3-07 TRASH/DEBRIS, JUNK, OVERGROWN VEG AND TREES IN ALLEY/ PLEASE F/U WITH NOV F/U.PN
Outstanding Inspections
Case Number: T07DV04165
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 10
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| VIOL - ILLEGAL ADDITION | None | Not Inspected | ||
| NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
| VIOL(BL) - DETACHED STRUCTURES | None | Not Inspected | ||
| VIOL(BL) - ATTACHED STRUCTURES | None | Not Inspected | ||
| VIOL(BL) - ROOF | None | Not Inspected | ||
| NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
| VIOL(EL) - CIRCUITS | None | Not Inspected | ||
| VIOL(EL)-SUBPANELS/DISCONNECTS | None | Not Inspected | ||
| VIOL(DL)-NUISANCE STRUCTURE(H) | None | Not Inspected | ||
| 06/20/2007 | NPO - REFUSE/TRASH/DEBRIS | JVALDEZ | Violation | MAIN STRUCTURE STUCCO EXTERIOR HAS MAJOR CRACKS ON THE EXTERIOR AND INTERIOR OF THE WALL. THE ROOFING PAPER HAS SEPARATED FROM THE PARAPET ON THE NORTHEAST CORNER OF THE ROOF, EXPOSING THE INTERIOR OF THE STRUCTURE. THE WOOD CONSTRUCTED ADDITION ATTACHED TO THE MAIN STRUCTURE IS DILAPIDATED. THE WOOD SLATES ARE DETERIORATED THE STUDS ARE INFESTED WITH TERMITES MULTIPLE DOORS, WINDOWS WERE FOUND OPEN TO UNAUTHORIZED ENTRY. THREE BROKEN WINDOWS ON THE SOUTH END OF THE DWELLING THE STRUCTURE WAS FOUND VACANT AND LACKING PROPER SIGNAGE NO TRESPASSING SIGNS ADDED CIRCUIT IN THE ATTACHED ADDITION JUNCTION BOX WITH ROMEX RUNNING MULTI CIRCUITS NOT PROPERLY INSTALLED. RECEPTACLE INSTALL UNDER THE EVE OF THE MAIN STRUCTURE NO WATER PROOF COVER ADDED CIRCUIT RUNNING UNDERGROUND TO A DETACHED STRUCTURE REAR OF PROPERTY. EXPOSED ROMEX WIRING AT THE DETACHED STRUCTURE . EXTERIOR SIDING ON THE STORAGE UNIT LACK PROTECTIVE TREATMENT. WINDOW SCREEN CASING LACKS TREATMENT WOOD DEBRIS, ANIMAL WASTE, BRANCHES, LITTER , ON THE PROPERTY 3 TO 4 FEET LARGE HOLE LOOKS LIKE AN OLD WELL. THE STATE OF THE HOLE IS HAZARDOUS TO FOOT TRAFFIC. NOTE ELECTRICAL SERVICE WAS IN A HAZARDOUS STATE THE DISCONNECT WAS DETACHING FROM THE STRUCTURE AND THE RISER WAS BENT BACK EXPOSING THE UTILITY CONDUCTORS THAT WERE ENERGIZED. CITY OF TUCSON DEPARTMENT OF NEIGHBORHOOD RESOURCES HAD TEP REMOVE THE METER AND REMOVE THE CONDUCTORS TO THE RISER. |
Completed Inspections
Case Status: COMPLIAN
Case Number: T07DV04165
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/20/2007 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Approved | MAIN STRUCTURE STUCCO EXTERIOR HAS MAJOR CRACKS ON THE EXTERIOR AND INTERIOR OF THE WALL. THE ROOFING PAPER HAS SEPARATED FROM THE PARAPET ON THE NORTHEAST CORNER OF THE ROOF, EXPOSING THE INTERIOR OF THE STRUCTURE. THE WOOD CONSTRUCTED ADDITION ATTACHED TO THE MAIN STRUCTURE IS DILAPIDATED. THE WOOD SLATES ARE DETERIORATED THE STUDS ARE INFESTED WITH TERMITES MULTIPLE DOORS, WINDOWS WERE FOUND OPEN TO UNAUTHORIZED ENTRY. THREE BROKEN WINDOWS ON THE SOUTH END OF THE DWELLING THE STRUCTURE WAS FOUND VACANT AND LACKING PROPER SIGNAGE NO TRESPASSING SIGNS ADDED CIRCUIT IN THE ATTACHED ADDITION JUNCTION BOX WITH ROMEX RUNNING MULTI CIRCUITS NOT PROPERLY INSTALLED. RECEPTACLE INSTALL UNDER THE EVE OF THE MAIN STRUCTURE NO WATER PROOF COVER ADDED CIRCUIT RUNNING UNDERGROUND TO A DETACHED STRUCTURE REAR OF PROPERTY. EXPOSED ROMEX WIRING AT THE DETACHED STRUCTURE EXTERIOR SIDING ON THE STORAGE UNIT LACK PROTECTIVE TREATMENT. WINDOW SCREEN CASING LACKS TREATMENT WOOD DEBRIS, ANIMAL WASTE, BRANCHES, LITTER , ON THE PROPERTY 3 TO 4 FEET LARGE HOLE LOOKS LIKE AN OLD WELL. THE STATE OF THE HOLE IS HAZARDOUS TO FOOT TRAFFIC. NOTE ELECTRICAL SERVICE WAS IN A HAZARDOUS STATE THE DISCONNECT WAS DETACHING FROM THE STRUCTURE AND THE RISER WAS BENT BACK EXPOSING THE UTILITY CONDUCTORS THAT WERE ENERGIZED. CITY OF TUCSON DEPARTMENT OF NEIGHBORHOOD RESOURCES HAD TEP REMOVE THE METER AND REMOVE THE CONDUCTORS TO THE RISER. |
| 08/14/2007 | INSP - FOLLOW UP CODE ENFORCE | JVALDEZ | Approved | STRUCTURE WAS DEMOLISHED AND DEBRIS REMOVED |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T07DV04165
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 06/26/2007 | CONTACTED IN PERSON |
| 06/26/2007 | CONTACTED BY MAILING |