Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

03/06/2007

Applicant:

WILKINS PHILIP C & VICKI L CP/RS

Description:

MICKEY MOUSE WIRING DONE WITH ELECT HEATER / PROPANE TANK IN HOUSE USED WITH HOT PLATE NO EXCAPE FOR FUMES OR SMOKE/BROKEN ELECT. POLES/ NO SMOKE ALARMS /NO STOVE IN HOME/ PARK NEEDS TO BE LOOKED AT AS A WHOLE VIOLATION. INSPECTOR WILL BE ABLE TO SEE THAT THE ELECT.WIRES ARE HOLDING UP THE POLES. 1D PASSED TO CSR FOR SCHEDULING SM 03/06/07

Outstanding Inspections

Case Number: T07DV02066
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
NPO(HC)-HEATING & VENTILATION None Not Inspected
NPO - SMOKE ALARMS None Not Inspected
03/14/2007 INSP - INITIAL CODE ENFORCMENT JVALDEZ Violation TWO HOTWATER HEATERS INSTALLED WITHOUT PERMITS BOTH UNITS ARE ON THE SAME GAS LINE AND ARE NOT MARKED. · BOTH UNITS VENT PIPE ARE UNDERNEATH THE EVE · NO COLD WATER SHUT OFF ON ONE OF THE UNITS · BOTH UNITS DO NOT HAVE DISCHARGE PIPES · ONE OF THE UNITS HAS A NON GAS RATED SHUT OFF GAS FURNACE INOPERABLE SPACE HEATER PERMANENTLY INSTALL. THE CORD CAP WAS CUT AND HARD WIRED INTO A RECEPTACLE IN LIVING ROOM NO SMOKE DETECTORS IN THE DWELLING. PROPANE STOVE BEING USED IN THE KITCHEN AREA. HOUSEHOLD COOKING TWO METER SERVICE SUB PANELS SERVICE EQUIPMENT INSTALLED WITHOUT PERMITS ATTACHED TO UNIT 20-1&2 PRIVATE OWNED EQUIPMENT SERVICE EQUIPMENT UNIT 20-1 MURRAY PANEL BOX HAS · MISMATCHED BREAKERS · NO BUSHING REAR OF PANEL · NO PLUG BOTTOM OF BOX SERVICE EQUIPMENT UNIT 20-2 SQUARE D PANEL BOX HAS · CONDUCTORS WERE CUT TO FIT INTO THE BACK FED OVER PROTECTION DEVICE · MISMATCHED BREAKERS WOODEN POST IS BROKEN AND SUPPORTING THE ELECTRICAL CONDUCTORS SUPPLING POWER TO THE PARK.

Completed Inspections

Case Status: COMPLIAN
Case Number: T07DV02066
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
09/07/2007 INSP - FOLLOW UP CODE ENFORCE JVALDEZ Approved ALL VIOLATIONS ABATED

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T07DV02066
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
03/14/2007 CONTACTED BY PHONE
03/14/2007 CONTACTED BY MAILING