Case: T06VL00850
Case Details
Entered Date:
06/28/2006
Applicant:
RITTER ROBERT R & MARIE JT/RS
Description:
HOUSE FIRE IN KITCHEN- ALARM # TBD
Completed Inspections
Case Status: COMPLIAN
Case Number: T06VL00850
Case Description: RES: FIRE
Total Completed Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/28/2006 | INITIAL CODE VIOLATION | RVIDAL | Approved | DAMAGE REPORT ELECTRICAL - METER BEING PULLED DUE TO WIRING NEED TO BE CHECKED IN CEILING AREA FOR HEAT AND WIRING AT EXHAUST HOOD HAS FIRE DAMAGE. PLUMBING - METER PINNED FOR GAS AND WATER METER OK. ALL OTHER PLUMBING OK, FIXTURE ON KITCHEN SINK MELTED. MECHANICAL - OK, WITH SMOKE DAMAGE TO DUCT WORK. BUILDING - MAIN STRUCTURE IS OK BUT KITCHEN HAD GREASE FIRE AT STOVE. HAS DRYWALL DAMAGE BY HEAT AND PULLED DOWN ON CEILING, CABINETS HAVE BEEN BURNED AND HAS SMOKE DAMAGE THROUGHOUT DWELLING. HAD PLYWOOD REMOVED TO CHECK FOR FIRE PENETRATION. PERMIT REQUIRED FOR ELECTRICAL AND GAS TO BE TURNED BACK WHICH REQUIRES CLEARANCE. WILL NEED PERMIT ON DRYWALL REPAIR AND ROOFING REPAIRS FOR PLYWOOD REPLACEMENT. PERMIT CAN BE OBTAINED AT 201 N STONE AVE BUILDING CON'T - CARPET AND VCT FLOORING HAS WATER DAMAGE. WINDOWS IN KITCHEN DAMAGED AND NEED TO BE REPLACED. BUILDING CON'T- CARPET AND V.C.T. FLOORING HAS WATER DAMAGE. WINDOWS IN KITCHEN DAMAGED AND NEED TO BE REPLACED. |
| 06/28/2006 | INITIAL CODE VIOLATION | RVIDAL | Approved | RECEIVED A CALL FROM COMMUNICATIONS THAT TFD ON SITE WITH HOUSE FIRE. ARRIVED AND HAD KITCHEN FIRE FROM GREASE ON STOVE. THE KITCHEN WAS DAMAGED WITH DRYWALL BEING PULLED DOWN ON CEILING TO CHECK FOR FIRE PENATRATION. WALLS, CABINETS WILL NEED TO BE REMOVED DUE TO FIRE OR HEAT DAMAGE. FLOORING WHICH WAS CARPET OR V.C.T. HAS WATER DAMAGE OR SMOKE DAMAGE. ALL ROOMS HAVE SMOKE DAMAGE AND HAD NO SMOKE DETECTORS. OWNER UNABLE TO SECURE BROKEN WINDOWS IN KITCHEN AND CITY WAS GIVEN PERMISSION TO SECURE. CALLED BATHCREST TO SECURE WINDOWS AND ROOF OPENINGS. WHILE ON SITE DOING SECUREMENT, THE OWNER SON REQUESTED THAT STORAGE ROOM DOORS BE BOARDED UP IN CARPORT AREA, ALSO DOING SIDE DOOR TO DWELLING. CALLED COMMUNICATION FOR TEP TO REMOVE METER DUE TO ELECTRICAL WIRING HAS SOME DAMAGE FROM THE HEAT AND AT EXHAUST HOOD HAS FIRE DAMAGE. GAS METER HAD ALREADY BEEN PINNED BY SOUTHWEST GAS. CALLED COMMUNICATION BACK DUE TO HAD A DEAD CAT AND WAS ASKING FOR E.T.A. FOR PICK-UP. WAS TOLD THAT CAT WOULD BE PICKED UP IN THE MORNING. RED CROSS WAS CALLED IN FOR PLACEMENT AND ONCE ARRANGEMENTS DONE, THEY LEFT THE SITE. ONCE GATES LOCKED, BUILDING SECURED LEFT THE SCENE. WATER WAS LEFT ON AND CHECKED FOR WATER LEAKS AND FOUND NONE. WILL CHECK IN 15 DAYS. |
| 08/18/2006 | FOLLOW UP CODE VIOLATION | RVIDAL | Approved | HOUSE VACANT AND SECURED. A DUMPSTER WAS REMOVED WHILE ON SITE. ITEMS HAVE BEEN REMOVED FROM INTERIOR OF DWELLING. WILL CHECK IN 60 DAYS. |
Completed Activity Special Conditions
Case Description - RES: FIRE
Case Number - T06VL00850
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 07/12/2006 | NOTICE OF VIOLATION ISSUED |
| 11/28/2006 | VIOLATION CLOSED. |