Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: AUTO INTO BLDG

Entered Date:

06/22/2006

Applicant:

MOORE RUSSELL

Description:

CAR INTO BUILDING

Completed Inspections

Case Status: COMPLIAN
Case Number: T06VL00815
Case Description: RES: AUTO INTO BLDG
Total Completed Inspections - 3
End Date Description Inspector Results Comments
06/22/2006 INITIAL CODE VIOLATION RVIDAL Approved COMMUNICATION CALLED THAT T.F.D ON SITE WITH CAR THRU-BUILDING. ARRIVED TO SITE AND POST ON CARPORT, AT MIDDLE BEAM HAD BEEN HOT AND AND ON GROUND. THE VEHICLE WAS NOT ON SITE BUT HAD ALSO HIT THE FRONT ENTRY AND CAVED IN THE MASONRY BLOCK WALL AT WINDOW AND DOOR. THERE WAS ELECTRICAL IN AREA HIT AND HAD TO TURN POWER OFF AT MAIN ELECTRICAL SERVICE. ASK FOR ELECTRICIAN TO COME TO SITE TO REMOVE BREAKERS TO TURN POWER TO UNIT. WHEN CHECKING FOR POWER BEING OFF, THE BEDROOM STILL HAD POWER. WHEN CHECKING MAIN DISCONNECT, FOUND TRIPLE LUGGING WHERE SUB-PANELS HAVE BEEN ADDED. TURN POWER OFF AT MAIN UNTIL ELECTRICIAN COULD FIGURE OUT HOW TO GET POWER OFF TO BEDROOM. PROPERTY MANAGEMENT HAD SOMEONE ON SITE TO SECURE OPENING ONCE POWER IS OFF.
06/22/2006 FOLLOW UP CODE VIOLATION RVIDAL Approved DAMAGE REPORT- AT FRONT DOOR ENTRANCE HAS WIRING FOR LIGHT, SWITCH AND OUTLET IN WALL THAT IS FALLING DOWN FROM IMPACT OF BEING HIT BY CAR. ELECTRICAL HAS BEEN TURNED OFF AT MAIN DUE TO CAN NOT TURN POWER TO UNIT B. PLUMBING OK. MECHANICAL OK, BUT LACKING EXHAUST FAN IN KITCHEN. BUILDING- FRONT ENTRANCE HAS BEEN HIT BY VEHICLE AND DAMAGE BLOCK, BREAKING WINDOW AND DOOR JAM AND SECURITY DOOR ARE TOTAL LOST. CARPORT IN FRONT OF UNIT HAS ONE POST THAT HAS BEEN HIT AND LACKING SUPPORT. PERMIT REQUIRED FOR ELECTRICAL BUILDING AND CAN BE OBTAINED AT 201 N STONE AVE AND INSPECT BY DEVELOPMENT SERVICES.
06/22/2006 INITIAL CODE VIOLATION RVIDAL Approved OWNER DID COME TO SITE BUT HAD TO LEAVE DUE TO AN APPOINTMENT. RUTH FROM MAMANGEMENT WAS MAKING CALLS FOR OWNER. TENANT WAS TOLD THAT HE WOULD NOT BE MOVING BACK DUE TO DAMAGE TO STRUCTURE AND PERSON THE HIT BUILDINGS WAS FRIEND OF HIS. TENANT WAS TOLD THAT HE COULD GET ITEMS OUT, THAT HE NEEDED TO MAKE ARRANGEMENT WITH THE MANAGEMENT. ONCE ELECTRICIAN GOT POWER OFF TO UNIT, ENTRANCE SECURED AND POST ADDED TO CARPORT, LEFT THE SCENE. WILL CHECK IN 15 DAYS.

Completed Activity Special Conditions

Case Description - RES: AUTO INTO BLDG
Case Number - T06VL00815
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
06/30/2006 NOTICE OF VIOLATION ISSUED
08/24/2006 VIOLATION CLOSED.

Documents

File Name Document Type  
None DOCUMENTS VIEW
2006-06-22 119.JPG IMAGES VIEW
2006-06-22 120.JPG IMAGES VIEW
2006-06-22 121.JPG IMAGES VIEW
2006-06-22 122.JPG IMAGES VIEW
2006-06-22 123.JPG IMAGES VIEW
2006-06-22 124.JPG IMAGES VIEW
2006-06-22 125.JPG IMAGES VIEW
2006-06-22 126.JPG IMAGES VIEW
2006-06-22 127.JPG IMAGES VIEW
2006-06-22 128.JPG IMAGES VIEW
2006-06-22 129.JPG IMAGES VIEW
2006-06-22 130.JPG IMAGES VIEW
2006-06-22 131.JPG IMAGES VIEW
2006-06-22 132.JPG IMAGES VIEW
2006-06-22 133.JPG IMAGES VIEW
2006-06-22 134.JPG IMAGES VIEW
2006-06-22 135.JPG IMAGES VIEW