Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

COM: AUTO INTO BLDG

Entered Date:

05/26/2006

Applicant:

FIRST INTERSTATE BANK OF AZ NA

Description:

CAR CRUSHED INTO A COMMERCIAL BUILDING (WELLS FARGO)

Completed Inspections

Case Status: COMPLIAN
Case Number: T06VL00692
Case Description: COM: AUTO INTO BLDG
Total Completed Inspections - 4
End Date Description Inspector Results Comments
05/26/2006 INITIAL CODE VIOLATION BWIESE Approved INDIDENT REPORT: AT 9:05 AM A 4-DOOR BUICK LESABRE TAG #NTR206 CRASHED THROUGH THE SOUTH WALL OF THE WELLS FARGO BANK. THE VEHICLE PENETRATED THE WALL 29" INTO THE INTERIOR OF THE BANK, CREATING AN 8 FEET WIDE BY 5 FEET HIGH EXTERIOR HOLE. CONSTRUCTION OF EXTERIOR WALL PENETRATED. LOAD BEARING WALL 2 X 6 WOOD STUDS, WITH 3/8 PLYWOOD AND 1" STUCCO SIDING. PLYWOOD & STUCCO COMPLETELY SHEARED. FOUR(4) 2 X 6 STUDS DISPLACED OFF BOTTOM PLATE. UPON ARRIVING AT SCENE, 10:15 AM, DNR INSPECTOR MET BY 1) TPD OFFICER M. JONES IN CAR #629, POLICE REPORT # IS 0605 26 0287 2) STEVE HAZEN OF HAZEN LTD. CONTRACTOR TO WELLS FARGO (SEE CARD) AND 3) WAYNE FREY ASSISTANT TO STEVE HAZEN 4) BANK MANAGER ANNETTA DERRICOTTE (SEE CARD). INTERIOR DAMAGE: DRYWALL SHEARED CREATING INTERIOR HOLE 8' X 8' 1) ELECTRICAL CABLE DISPLACED BUT NO APPARENT ELECTRICAL DANGER 2) SOME TELEPHONE & COMPUTER CABLES WERE DISPLACED. 3) OFFICE FURNITURE CONSISTING OF WALL CABINETS AND DESKS HAVE BEEN DAMAGED. NO ONE WAS INJURED. DAMAGE DOES NOT APPEAR TO HAVE COMPROMISED THE BANK'S PLUMBING OR INTERIOR LIGHTING. HEATING/COOLING HAS BEEN COMPROMISED DUE TO OPEN HOLE IN WALL, BUT INTERIOR TEMPERATURE IS GOOD. ACTION TAKEN: 1) CAR REMOVED BY TOW TRUCK. 2) SIDEWALK HAS BEEN ROPED OFF W/ YELLOW POLICE BARRIER TAPE 3) PARKING SPACES IN FRONT OF AND ADJACENT TO IMPACT HAVE BEEN BLOCKED OFF W/ ORANGE CONES. 4) A GUARD FOR THE EXTERIOR OF IMPACT SITE HAS BEEN REQUESTED.
05/26/2006 INITIAL CODE VIOLATION GGOODMAN Approved VISITED SITE, WAS MET BY CONTRACTOR STEVE HAZEN, STEVE MENTIONED THAT HE WAS CALLED BY WELLS FARGO BANK SHORTLY AFTER THE ACCIDENT HAD HAPPENED. ALSO MENTIONED THIS WAS THE 3RD THEY HAD BEEN CALLED BY WFB ON SIMILIAR OCCASIONS. STEVE WENT OVER THE DAMAGE WITH DNR INSPECTORS AND THEN EXPLAINED HIS INTENTIONS ABOUT REPAIRS. (COVERED IN BRIAN WIESE'S REPORT) MET WITH POLICE OFFICER M. JONES WHO EXPLAINED HOW THE ACCIDENT HAPPENED, GAVE THE POLICE REPORT NUMBER (0605 26 0287) MENTIONED HE WOULD COMPLETE THE REPORT AND REPORT WOULD BE AVAILABLE AT THE POLICE DEPARTMENT. ASKED IF IT WAS OK TO REMOVE THE VEHICLE. AFTER COMPLETING OUR INSPECTION INSIDE CLEARED THE BUILDING FOR REMOVAL OF VEHICLE. MET WITH BANK MANAGER ANNETTA DERRICOTTE, EXPLAINED TO HER WHO WE WERE, THAT WE HAD ASSESSED THE DAMAGE AND FELT IT WAS OK TO REMOVE THE CAR. EXPLAINED THAT WE WOULD BE ISSUING A NOV FOR BUILDING AND BUILDING ACCESSIBILITY, MENTIONED THAT WE WERE AWARE WORK TO ABATE THE ISSUE WOULD BE COMPLETED TODAY, 5/26/06, THAT STEVE HAZEN MENTIONED HE WOULD PULL A PERMIT FOR CAR ON 5/30/06 AND WOULD CALL FOR WORK TO BE INSPECTED 5/31/06 OR 6/01/06. ISSUED A NOV, NOV WAS SIGNED FOR BY JANE LANCASTER, COPY GIVEN TO BANK, TO STEVE HAZEN, WILL SEND COPY TO OWNERS IF NECESSARY. (SEE BRIAN WIESE REPORT FOR DETAILS)
05/26/2006 INITIAL CODE VIOLATION GGOODMAN Approved DAMAGE REPORT ADDRESS: 8951 E TANQUE VERDE RD OWNER/OCCUPANT: FIRST BANK OF AZ NA ATTN: WELLS FARGO BANK PHONE: 792-5310 CAUSE OF DAMAGE: PRIVATELY OWNED VEHICLE RAN INTO WALL LOCATION OF DAMAGE: SOUTH WALL BETWEEN THE ENTRY DOORS AND S/E CORNER OF THE STRUCTURE BUILDING: 4 - 5 STUDS OF STRUCTURAL WALL WERE PUSHED AWAY FROM THE BOTTOM PLATE, ALL STUDS CRACKED AT THE 8' MARK, 3/8 SHEER WALL DAMAGED, STUCCO AND DRYWALL DAMAGED. ELECTRICAL: N/A PLUMBING: N/A MECHANICAL: N/A SUMMARY OF REMARKS: CONTRACTOR STEVE HAZEN WAS ON SITE AT TIME OF ARRIVAL, PROPOSED TO INSTALL A 6 X 12 BEAM OR GLUE LAMB AT 8' AND DOWN TRIMMERS ON EITHER SIDE CRIPPLES UNDERNEATH THE BEAM, AND RE-SECURE 3/8" SHEER WALL. DNR INSPECTOR DETERMINED IT WAS OK TO REMOVE CAR. CAR WAS REMOVED. MATERIALS ARRIVED APPROX 11:45, WORK BEGAN APPROX 12:10, MR HAZEN TO PULL PERMIT TUES. NOV ISSUED.
07/31/2006 FOLLOW UP CODE VIOLATION GGOODMAN Approved VISITED SITE, TOOK PICTURES, FOUND THAT EXTERIOR STUCCO HAD BEEN PATCHED AND PAINTED TO MATCH THE EXSITING STUCCO. INTERIOR FOUND DRYWALL HAD ALSO BEEN REPAIRED. DRYWALL PATCHED TO MATCH THE EXSITING AND CEILING TILES ELECTRICAL RACEWAYS HAD BEEN REPLACED BACK INTO THE DESK AREA'S AND DESKS PUT BACK INTO PLACE. DNR HAS NO FURTHER ISSUES. COMPLIANCE, CASE CLOSED!!

Completed Activity Special Conditions

Case Description - COM: AUTO INTO BLDG
Case Number - T06VL00692
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
05/30/2006 CONTACTED BY PHONE
05/30/2006 NOTICE OF VIOLATION ISSUED
08/01/2006 VIOLATION CLOSED.