Status:

COMPLETE

Type:

INSPECTION

Entered Date:

12/29/2006

Applicant:

B & B CLARK PROPERTIES LLC

Description:

Full inspection

Completed Inspections

Case Status: COMPLETE
Case Number: T06FR02946
Case Description: INSPECTION
Total Completed Inspections - 9
End Date Description Inspector Results Comments
04/28/2006 VIOL - FIRE PROTECTION SYSTEMS DRAMIREZ Approved TFC 901.6 Automatic sprinkler systems shall be inspected, tested and maintained. Shall provide documentation of inspection.
04/28/2006 INSP - FULL DRAMIREZ Approved
12/29/2006 VIOL - FIRE SERVICE FEATURES DRAMIREZ Approved TFC 505.1 Building shall be identified with address numbers that are plainly legible and visable from the street.
12/29/2006 VIOL - FIRE RESIST.RATED CONST DRAMIREZ Approved TFC 703.1 Damaged ceiling tiles in main office and waitress area shall be repaired or replaced.
12/29/2006 VIOL - COMPRESSED GASES DRAMIREZ Approved TFC 3003.3 Compressed gas cylinders shall be secured against accidental dislodgement.
12/29/2006 VIOL - MEANS OF EGRESS DRAMIREZ Approved TFC 1008.1.8 Egress doors shall readily openable from the egress side without the use of a key or special knowledge. Keyed lock on kitchen exit door shall be replaced with a thumb-turn lock.
12/29/2006 VIOL - MEANS OF EGRESS DRAMIREZ Approved TFC 1026.5 Emergency back-up lighting shall be provided in case of a power failure.
12/29/2006 VIOL - MEANS OF EGRESS DRAMIREZ Approved TFC 1011.2 Exit signs shall be internally or externally illuminated.
12/29/2006 VIOL - MEANS OF EGRESS DRAMIREZ Approved TFC 1008.1.8.3 Main exterior door is permited to be equipped with key-operated lock provided as sign is posted adjacent to the door reading "THIS DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED"