Case: T06FR02940
Case Details
Entered Date:
12/29/2006
Applicant:
GARNER JAMES B & CARLENE CP/RS
Description:
Full inspection
Completed Inspections
Case Status: COMPLETE
Case Number: T06FR02940
Case Description: INSPECTION
Total Completed Inspections - 9
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2006 | VIOL - WELDING & OTHER HOT WRK | DRAMIREZ | Approved | TFC 2604.1.1 Shall provide protection for sparks, slag or heat from igniting exposed combustibles when welding. |
| 12/29/2006 | VIOL - COMPRESSED GASES | DRAMIREZ | Approved | TFC 3003.3 Compressed gas cylinders shall be secured against accidental dislodgement. |
| 12/29/2006 | VIOL - PRECAUTION AGAINST FIRE | DRAMIREZ | Approved | TFC 310.2 Smoking shall be prohibited where flammable and commbustible materials are stored or handled. A "NO SMOKING" sign shall be posted where "Hot Work" equipment is used pr stored. |
| 12/29/2006 | VIOL - BUILDING SVCS & SYSTEMS | DRAMIREZ | Approved | TFC 605.6 Open junction boxes and open-wiring shall be prohibited. Approved covers shall be provided for for all switch and elecrtical boxes. |
| 12/29/2006 | VIOL - BUILDING SVCS & SYSTEMS | DRAMIREZ | Approved | TFC 605.5 Extension cords shall not be substituted for permanent wiring. |
| 12/29/2006 | VIOL - BUILDING SVCS & SYSTEMS | DRAMIREZ | Approved | TFC 605.4 Multiplug adaptors such as cube adaptors are prohibited. |
| 12/29/2006 | VIOL - MEANS OF EGRESS | DRAMIREZ | Approved | TFC 1008.1.8 Egress doors shall be readily openable from the egress side without the use of a key or special knowledge. A thumb-turn lock shall be provided for the exit door to main shop area. |
| 12/29/2006 | VIOL - MEANS OF EGRESS | DRAMIREZ | Approved | TFC 1008.1.8.3 Main exterior door is permitted to be equipped with key operated lock provided a sign is posted adjacent to the door reading " THIS DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED". |
| 12/29/2006 | INSP - FULL | DRAMIREZ | Approved |