Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

11/30/2006

Applicant:

BRYMAR ENTERPRISES LLC

Description:

FULL FIRE INSPETION CHECKLIST USED

Completed Inspections

Case Status: COMPLETE
Case Number: T06FR02805
Case Description: INSPECTION
Total Completed Inspections - 10
End Date Description Inspector Results Comments
11/30/2006 VIOL - MEANS OF EGRESS SHIGGINB Approved 26.TFC 1008.18 Door operation No double key dead-bolt locks, no special knowledge needed, no slide bolt locks. Only one unlatching device, Except group R’s can have night latch, indicating dead bolt, or security chain on exits only. 1. REMOVE LATCH TYPE LOCK FROM FRONT DOOR, MAY USE A HOTEL NIGHT SWING LOCK
11/30/2006 VIOL - FIRE RESIST.RATED CONST SHIGGINB Approved 18.TFC 703.1Must be repair w/ fire resistive materials Look behind washers and dryers, hot water heaters, heater closets. 1. REPAIR DRYWALL BEHIND DRYER AND MOVE DRAIN PIPE OUT SIDE THE DRYWALL
11/30/2006 VIOL - EMERGENCY PLAN/PREPARE SHIGGINB Approved 15. TFC 901.6.2 Records of all system inspections, tests, and maintenance required by the referenced standards shall be maintained on the premises for a minimum of 3 years and made available to the fire code official upon request. 1. SHOW ALL DOCUMENTATION FOR FIRE DRILLS AND SMAKE ALARM TESTING
11/30/2006 VIOL - FIRE PROTECTION SYSTEMS SHIGGINB Approved 33.TFC 906.1 # 6 Extinguishers required by code official. 1. UNABLE TO FIND FIRE EXTINGUSHER, EITHER SIGN OR MOVE TO BETTER LOCATION.
11/30/2006 VIOL - FIRE PROTECTION SYSTEMS SHIGGINB Approved 32. TFC 907.2.10 Smoke alarms Check for operation and location. Min. is bedrooms and hallway. 1. ALL SMOKE ALARMS MUST BE BETWEEN 4" AND 12" FROM THE CEILING IF ON A WALL AND 4" FROM CORNER IF ON CEILING. ( BEDROOM 7 AND LIVING ROOM
11/30/2006 VIOL - BUILDING SVCS & SYSTEMS SHIGGINB Approved 20. TFC 605.5 Extension cords Grounds, used as permanent wiring, run under carpet, attached to walls can be replaced w/ power strip that has overcurrent protection 1.REMOVE EXTENSION CORDS IN BEDROOMS, 2,6 AND 5, LIVING ROOM ( TV) AND BACK PORCH. CAN REPLACE WITH SURGE PROTECTED POWER TAPS.
11/30/2006 VIOL - BUILDING SVCS & SYSTEMS SHIGGINB Approved 6. TFC 605.1 Abatement of electrical hazards Exposed electrical wires , covers, and panels locked. Undergroud romex can be above 7’ and not in conduit, if protected from UV light and damage. 1. ELECTRICAL WIRES ON N AND S SIDES OF HOME AND SIDE PORCH, MUST SECURED PROPERTY AND PROTECT FROM SUN DAMAGE. 2.POLE ON S. PORCH THAT LEADS TO FOUNTAIN, WIRE MUST BE REPLACE AND PLACED IN CONDUTE
11/30/2006 VIOL - FIRE SERVICE FEATURES SHIGGINB Approved 4. TFC 506.1 Security devices hindering access A knots box may be required if security devices block access. 1. WINDOW IN 1# BEDROOM IS BLOCKED BY BUSH, CUT BUSH BACK
11/30/2006 VIOL - PRECAUTION AGAINST FIRE SHIGGINB Approved 2. TFC 304.1.2 Excessive combustibles Must be safe for non self preserving residents. Weeds over 6” high, Look at alleys and around gas meters. Laddering of vegetation to home. 1. WEEDS IN ALLEY MUST BE CUT DOWN
11/30/2006 INSP - FULL SHIGGINB Approved ASSISTED LIVINF LIC FOR 9 3 YR INSPECTION CYCLE