Case: T06FR02448
Case Details
Entered Date:
08/16/2006
Applicant:
QUIJADA MARTHA YOLANDA
Description:
FIRE INSPECTION CHECK L IST USED
Completed Inspections
Case Status: COMPLETE
Case Number: T06FR02448
Case Description: INSPECTION
Total Completed Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2006 | VIOL - FIRE PROTECTION SYSTEMS | SHIGGINB | Approved | 32. TFC 907.2.10 Smoke alarms Check for operation and location. Min. is bedrooms and hallway 1. REPAIR SMOKE ALARM IN BEDROOM # 6, AND LAUNTRY ROOM, AND OFFICE. 2. SMOKE ALARM IN DINING TO LOW, MUST BETWEEN 4 TO 12" FROM CEILING OR ON CEILING. |
| 12/28/2006 | VIOL - BUILDING SVCS & SYSTEMS | SHIGGINB | Approved | 20. TFC 605.5 Extension cords Grounds, used as permanent wiring, run under carpet, attached to walls can be replaced w/ power strip that has overcurrent protection. 1. REMOVE EXTEN. CORD IN NE BEDROOM AND IN BEDROOM # 7. |
| 12/28/2006 | VIOL - BUILDING SVCS & SYSTEMS | SHIGGINB | Approved | 21.TFC 605.4 Multi-plugs and power-taps UL listed,No end to end, home made. 1. REMOVE MULTI-PLUG ADAPTERS IN LIVING ROOM AND BEDROOM # 8. MAY REPLACE W/ A PROTECTED POWER TAP. |
| 12/28/2006 | VIOL - BUILDING SVCS & SYSTEMS | SHIGGINB | Approved | 6. TFC 605.1 Abatement of electrical hazards Exposed electrical wires , covers, and panels locked. Undergroud romex can be above 7’ and not in conduit, if protected from UV light and damage. 1. SECURE ELEC. WIRE UNDER EVES ON FRONT PORCH 2. EXPOSED ELEC. WIRE N. SIDE OF BUILDING. ABOVE ELEC. PANEL NEEDS TO PLACE IN CONDUTE. |
| 12/28/2006 | VIOL - FIRE SERVICE FEATURES | SHIGGINB | Approved | 3. TFC 503.1.1 Emergency Unit access Apparatus must be able to get within 150’, around the building. Fire lanes 20’w x 15’h. 1.MUST HAVE FIRE DEPART. ACCESS FOR FRONT GATE. ( MAY NEED A KNOT BOX ) |
| 12/28/2006 | VIOL - PRECAUTION AGAINST FIRE | SHIGGINB | Approved | 2. TFC 304.1.2 Excessive combustibles Must be safe for non self preserving residents. Weeds over 6” high, Look at alleys and around gas meters. Laddering of vegetation to home. 1. TRIM BUSHES AND TREES, KEEP 3' AWAY FROM BUILDING. |
| 12/28/2006 | INSP - FULL | SHIGGINB | Approved | FULL FIRE INSPECTION IFC 2003 CODE USED ASL HOME LIC FOR 10 |